Note that this article replaces KnowledgeBase 4EGFP8XD: LabVIEW RT Memory Usage on FieldPoint Controllers. Some NI manuals may still reference the previous document. If you were redirected from the previous KnowledgeBase URL, please update your bookmarks accordingly.
LabVIEW RT/ NI-FieldPoint software versions | Memory usage at runtime (MB) | |
---|---|---|
Full (1) | Min (2) | |
8.0 - 5.0 | 11.5 | 12.0 |
8.2.1 - 5.0.1 | 12.0 | 12.1 |
8.5 - 6.0 | 13.5 | 13.7 |
8.5.1 - 6.0.1 | 13.5 | 13.8 |
8.6 and later | Not supported | Not supported |
LabVIEW RT/ NI-FieldPoint software versions | Size of installed driver in nonvolatile memory (MB) | |
---|---|---|
Full (1) | Min (2) | |
8.0/5.0 | 6.3 | 6.0 |
8.2.1/5.0.1 | 12.6 | 9.0 |
8.5/6.0 | 13.6 | 9.5 |
8.5.1/6.0.1 | 15.0 | 10.4 |
8.6/6.0.3 | 15.5 | 11.4 |
8.6.1/6.0.4 | 15.6 | 11.5 |
2009/6.0.5 | 17.0 | 12.4 |
2009 SP1/6.0.6F1 | 18.8 | 12.6 |
2010/6.0.7 | 21.3 | 14.0 |
2010 SP1/6.0.8 | 26.2 | 14.2 |
2011/6.0.9 | 32.6 | 16.2 |
2011 SP1/6.0.10 | 31.0 | 14.7 |
2012/6.0.11 | 34.6 | 16.0 |
LabVIEW RT/ NI-FieldPoint software versions | Memory usage at runtime (MB) | |
---|---|---|
Full (1) | Min (2) | |
8.0/5.0 | 8.7 | 8.0 |
8.2.1/5.0.1 | 16.4 | 11.5 |
8.5/6.0 | 17.4 | 12.0 |
8.5.1/6.0.1 | 19.9 | 13.5 |
8.6/6.0.3 | 20.0 | 14.1 |
8.6.1/6.0.4 | 20.2 | 14.2 |
2009/6.0.5 | 20.7 | 15.8 |
2009 SP1/6.0.6f1 | 24.7 | 17.7 |
2010/6.0.7 | 27.3 | 20.0 |
2010 SP1/6.0.8 | 26.7 | 19.2 |
2011/6.0.9 | 31.6 | 20.4 |
2011 SP1/6.0.10 | 30.9 | 19.6 |
2012/6.0.11 | 23.4 | 19.0 |
Notes:
(1) Includes DataSocket for LabVIEW RT, FieldPoint Drivers and VI Manager, LabVIEW Real-Time Module, PID Control Toolkit, Modbus I/O Server, NI Serial RT, NI-VISA, NI-Watchdog, Network Variable Engine and Variable Client Support for LabVIEW RT.
(2) Contains only FieldPoint Drivers, FieldPoint VI Manager, LabVIEW Real-Time Module, Language Support and NI-Watchdog.
(3) FieldPoint Recommended Software Set without any additional Option.
(4) Minimal FieldPoint Recommended Software Set without any additional Option.
LabVIEW RT/ NI-FieldPoint software versions | Memory usage at runtime (MB) | |
---|---|---|
Full (1)(3) | Min (2)(4) | |
8.5.1/6.0.1 | 20.2 | 13.6 |
8.6/6.0.3 | 21.8 | 14.8 |
8.6.1/6.0.4 | 22.2 | 16.2 |
2009/6.0.5 | 21.2 | 15.3 |
2009SP1/6.0.6f1 | 27.0 | 16.2 |
2010/6.0.7 | 29.4 | 16.2 |
2010SP1/6.0.8 | 31.2 | 17.0 |
2011/6.0.9 | 35.0 | 18.0 |
2011SP1/6.0.10 | 36.0 | 18.0 |
2012/6.0.11 | 42.0 | 19.0 |
LabVIEW RT/ NI-FieldPoint software versions | Memory usage at runtime (MB) | |
---|---|---|
Full (1)(3) | Min (2)(4) | |
8.5.1/6.0.1 | 31.6 | 20.8 |
8.6/6.0.3 | 34.4 | 23.0 |
8.6.1/6.0.4 | 34.6 | 24.0 |
2009/6.0.5 | 37.0 | 26.7 |
2009SP1/6.0.6f1 | 37.3 | 26.3 |
2010/6.0.7 | 39.7 | 26.8 |
2010SP1/6.0.8 | 38.9 | 25.8 |
2011/6.0.9 | 48.0 | 29.0 |
2011SP1/6.0.10 | 58.0 | 27.0 |
2012/6.0.11 | 58.0 | 27.0 |
Notes:
(1) Includes DataSocket for LabVIEW RT, FieldPoint Drivers and VI Manager, LabVIEW Real-Time Module, Modbus I/O Server, NI-Serial, NI-VISA, NI Watchdog, Network Variable Engine and Variable Client Support for LabVIEW Real-Time.
(2) Contains only FieldPoint Drivers, FieldPoint VI Manager, LabVIEW Real-Time Module and NI Watchdog.
(3) FieldPoint Recommended Software Set without any additional Option.