This document contains the PXI Platform Services known issues that were discovered before and since the release of PXI Platform Services 2024 Q4. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.
Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1448861, 1482726, 1482726 |
System Crashes When NI Drivers Exceed the Default Max for iNotify InstancesWhen running code that initializes NI drivers, the system crashes. This may be because the NI drivers have requested more than the 128 iNotify instances that the default Linux kernel allows. The likelihood of encountering this issue increases as the number of installed drivers increases.
Workaround: Increase the iNotify limit from the default 128 to a larger number, such as 12288. You can increase the iNotify limit permanently through the following:
sudo sysctl -w fs.inotify.max_user_instances=<Upper Limit> Note: <Upper Limit> can be any large number such as 12288. |
Reported Version: N/A Resolved Version: N/A Added: Jul 27, 2021 |
|
1210589 |
NI Drivers may fail under Linux kernel DMA remappingAttempts to use NI devices may fail on Linux kernels that have enabled DMA remapping. The Linux kernel logs will contain errors similar to the following: Linux distributions that enable DMA remapping by default include Ubuntu 22.04 with kernel 6.8 or higher and Ubuntu 24.04.
Workaround: Modify the Linux kernel DMA remapping configuration as outlined in https://www.ni.com/r/iommu-linux.
|
Reported Version: NI Linux Device Drivers: 2020 | PXI Platform Services: 20.0 Resolved Version: N/A Added: Nov 1, 2024 |
Issues found in this section will not be listed in future known issues documents for this product.
There are currently no issues to list.