The following items are notable issues fixed between the release of NI-Sync 21.0 and NI-Sync 21.3, including additional patches and service packs. If you have an issue ID, you can search this list to validate that the issue has been fixed. This is not an exhaustive list of issues fixed in the current version of NI-Sync.
Bug Number |
Legacy ID |
Description |
Details |
---|---|---|---|
1359917 |
NI-Sync skews system clock to conform to TSN clockWhen setting the system time on a NI Linux RT RIO controller with NI-Sync installed, the system clock will skew by a factor of 10/9 until the offset is corrected, instead of immediately snapping back. Workaround: Follow the steps listed in this document or uninstall NI-Sync if it is not needed.
|
Reported Version: NI-Sync 16.0 Resolved Version: NI-Sync 21.3 Added: N/A |
|
1509459 | 399570 |
LabVIEW Slows Down When NI-Sync Terminal Control is Created on Linux RT SystemWhen a user creates an NI-Sync terminal control or constant in a VI in the context of a Linux RT target, LabVIEW becomes slow in responding to edit actions, including dragging and placing nodes on the block diagram. Workaround: To prevent the sluggishness in LabVIEW, do the following:
|
Reported Version: NI-Sync: 20.1 Resolved Version: NI-Sync: 21.3 Added: Jul 27, 2021 |
Installing some patches may require certain additional steps or considerations. Please refer to the following table for more information about patches for this release.
These patches currently do not have any special instructions.