NI does not actively maintain this document.
This content provides support for older products and technology, so you may notice outdated links or obsolete information about operating systems or other relevant products.
Each issue appears as a row in the table and includes the following fields:
504246 | — | In rare instances, a Kintex-7 FPGA target may not download or change successfully in an NI PXI-1082 chassis. |
503037 | — | 659xR Board Driver sessions do not handle RIO Remoting well |
ID | Known Issue | |||||
---|---|---|---|---|---|---|
504246 Return | In rare instances, a Kintex-7 FPGA target may not download or change successfully in an NI PXI-1082 chassis. In rare instances, a Kintex-7 FPGA target may not download or change successfully in an NI PXI-1082 chassis. Workaround: Reboot the NI PXI-1082 chassis.
| |||||
503037 Return | 659xR Board Driver sessions do not handle RIO Remoting well Board Driver methods (read temperature, power, and frequency counters) do not handle remote devices well. If you have a local device with the same RIO interface number as the remote device you are trying to access, you will read the power of the local device instead of the remote device. Workaround: Do not have any RIO devices on host computer.
|
Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.