NI LabVIEW Instrument Design Libraries for IF Digitizers 15.0 Known Issues

Overview

This document contains the NI LabVIEW Instrument Design Libraries for IF Digitizers 15.0 (the Instrument Design Libraries) known issues that were discovered since the release of the Instrument Design Libraries. Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that can be encountered.

Known Issues by Severity

480524Windows 8.0 to Windows 8.1 upgrade issue
504244In rare instances, a Kintex-7 FPGA target may not download or change successfully in an NI PXI-1082 chassis.

 

IDKnown Issue
480524
Windows 8.0 to Windows 8.1 upgrade issue
Upgrading the version of Windows on a system with this driver installed may result in the loss of device names, the loss of device configuration, and/or devices appearing disconnected. For more information about how to resolve this issue, visit ni.com/info and enter the Info Code 'excrxm'.

Workaround: N/A

Reported Version: 14.0  Resolved Version: N/A  Added: 11/10/2014
504244
In rare instances, a Kintex-7 FPGA target may not download or change successfully in an NI PXI-1082 chassis.

Workaround: Reboot the NI PXI-1082 chassis.

Reported Version: 14.0  Resolved Version: N/A  Added: 11/10/2014

Related Topics

 

Contacting NI

Contact NI regarding this document or issues in the document. If you contact NI in regards to a specific issue, reference the ID number given in the document. The ID number contains the current issue ID number as well as the legacy ID number (use the current ID number when contacting NI). You can contact us through any of the normal support channels including phone, email, or the discussion forums. Visit the NI Website to contact us. Also contact us if you find a workaround for an issue that is not listed in the document.

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).