From Friday, April 19th (11:00 PM CDT) through Saturday, April 20th (2:00 PM CDT), 2024, ni.com will undergo system upgrades that may result in temporary service interruption.

We appreciate your patience as we improve our online experience.

LabVIEW 2023 Q1 Known Issues

Overview

This document contains the  LabVIEW known issues that were discovered before and since the release of  LabVIEW 2023 Q1. Known issues are performance issues or technical bugs that NI has acknowledged exist within this version of the product.

 

Not every issue known to NI appears on this list; it is intended to show the most severe and common issues that you may encounter and provide workarounds when possible. Other technical issues that you may encounter could occur through normal product use or system compatibility issues. You may find more information on these issues in NI’s Product Documentation, Knowledgebase, or Community; see Additional Resources.

Bug Number

Legacy ID

Description

Details

1335783, 1859807, 2065508

Using the DAQAssistant with DAQmx 2022 Q3 on LabVIEW 2022 Q3 Fails to Generate Code

Using the DAQAssistant on LabVIEW 2022 Q3 with DAQmx 2022 Q3 installed fails to configure the DAQAssistant node and gives the following code generation error:
"LabVIEW Code Generation failed to execute. This may occur if the code gen engine is not properly installed, or if you are using a LabVIEW version under development" . 

Other workflows that use the DAQ Assistant to generate DAQmx tasks also fail.

Workaround:

Install NI-DAQmx 2024 Q1 or later. Alternatively, install LabVIEW 2021 SP1

  • LabVIEW 2021 SP1 does not need to be activated, it is sufficient to install LabVIEW 2021 on your system and not activate it
  • Installing just the LabVIEW 2021 SP1 run-time engine will not be sufficient, the LabVIEW ADE needs to be installed 

Reported Version:

LabVIEW 2022 Q3 | NI-DAQmx 2022 Q3 | NI-DAQmx 2023 Q1

Resolved Version:

NI-DAQmx 2024 Q1

Added:

Aug 2, 2022

2052750

Same Version of LabVIEW Is Listed Twice in Software Section of NI MAX

Workaround:

There is currently no known workaround for this issue.

Reported Version:

LabVIEW 2022 Q3

Resolved Version:

N/A

Added:

Jul 26, 2022

2262038

File Dialog Does Not Support Some Patterns That Worked in Earlier Versions

The File Dialog no longer works with NULL characters in the Pattern input to present multiple filters. This change in behavior can affect applications that were built with the option "Allow future version of LV Runtime to run the application."

Workaround:

There is currently no known workaround for this issue.

Reported Version:

LabVIEW 2022 Q3

Resolved Version:

N/A

Added:

Feb 9, 2023

2263807

Activate Button Does Not Work in LabVIEW Evaluation Reminder Dialog



Workaround:

Use Help>Activate LabVIEW Components from the LabVIEW menu or run the NI License Manager.

Reported Version:

LabVIEW 2023 Q1

Resolved Version:

N/A

Added:

Feb 9, 2023

2342514

Open Venv Python Session.vi Does Not Work For Paths With Spaces

Open Virtual Environment Session.vi with the Open Venv Python Session configuration returns error 1671 ("Error creating python session") if the Env path contains any spaces.

Workaround:

Create a directory hard symlink via mklink /J that does not contain spaces and use that path in LabVIEW.

Reported Version:

LabVIEW 2023 Q1

Resolved Version:

N/A

Added:

May 2, 2023

Final Time Issue Listed

Issues found in this section will not be listed in future known issues documents for this product.

There are currently no issues to list.

Additional Resources

Explore Support Content and Product Documentation 

 

 

Ask the NI Community

 

 

Request Support from an Engineer

 

A valid service agreement may be required, and support options vary by country

 

Glossary of Terms

 

  • Bug ID - When an issue is reported to NI, you may be given this ID or find it on ni.com.  You may also find IDs posted by NI on the discussion forums or in KnowledgeBase articles.
  • Legacy ID – An older issue ID that refers to the same issue.  You may instead find this issue ID in older known issues documents.
  • Description - A few sentences which describe the problem. The brief description given does not necessarily describe the problem in full detail.
  • Workaround - Possible ways to work around the problem.
  • Reported Version - The earliest version in which the issue was reported.
  • Resolved Version - Version in which the issue was resolved or was no longer applicable. "N/A" indicates that the issue has not been resolved.
  • Date Added - The date the issue was added to the document (not the reported date).