ni.com checkout is currently experiencing issues.
Support teams are actively working on the resolution.
ni.com checkout is currently experiencing issues.
Support teams are actively working on the resolution.
End of Life Products | Replacement Products (if available) | Notes | |
Model Number | X Series Model Number (PCIe/PXIe) | M Series Model Number (PCI/PXI) | Applies to all: NI-DAQmx driver software required |
PCI-6010 | PCIe-6320 | PCI-6220 | |
PCI-6013 | PCIe-6320 | PCI-6220 | |
PCI-6014 | PCIe-6321 | PCI-6221 | |
PCI-6023 | PCIe-6320 | PCI-6220 | |
PCI-6024 | PCIe-6321 | PCI-6221 | |
PCI-6025 | PCIe-6323 | PCI-6229 | |
PCI-6034 | PCIe-6320 | PCI-6220 | |
PCI-6035E | PCIe-6321 | PCI-6221 | |
PCI-6036E | PCIe-6321 | PCI-6221 | |
PCI-6040E | PCIe-6341 | PCI-6251 | |
PCI-6052 | PCIe-6341 | PCI-6251 | |
PCI-6070E | PCIe-6351 | PCI-6251 | |
PCI-6071E | None | PCI-6255 | |
PXI-6025 | PXIe-6341 | PXI-6229 | |
PXI-6040E | PXIe-6341 | PXI-6251 | |
PXI-6052E | PXIe-6341 | PXI-6251 | |
PXI-6070E | PXIe-6361 | PXI-6251 | |
PXI-6071E | PXIe-6355 | PXI-6255 |
End of Life Products | Replacement Products (if available) | Notes | ||||
SCXI Model Number | Channels | PXI Model Number | Channels | C Series Model Number | Channels | |
SCXI-1100 SCXI-1102 SCXI-1102B SCXI-1102C | 32 | Thermocouple Measurement: PXIe-4353 with TB-4353 or TC-4353 | 32 | Thermocouple Measurement: NI 9210 | 4 | |
Thermocouple Measurement: NI 9213 NI 9214 | 16 | |||||
Current Measurement: PXI-6236 | 2 | Current Measurement: NI 9203 | 8 | |||
Current Measurement: PXI-6238 PXI-6239 | 4 | Current Measurement: NI 9208 | 16 | |||
Voltage Measurement: PXIe-63xx | 8-104 | Voltage Measurement: NI 9205 | 32 | |||
Voltage Measurement: NI 9220 | 16 | |||||
RTD Measurement: PXIe-4357 | 20 | RTD Measurement: NI 9217 | 4 | |||
SCXI-1104 SCXI-1104C | 32 | PXIe-4304 or PXIe-4305 | 32 | NI 9221 NI 9228 | 8 | PXIe-4304 and PXIe-4305 include 2kHz filter instead of 10kHz filter; 42V range |
NI 9229 | 4 | |||||
SCXI-1112 | 8 | PXIe-4353 with TC-4353 | 32 | Thermocouple Measurement: NI 9210 | 4 | C-Series options offer screw terminal connectivity |
Thermocouple Measurement: NI 9213 NI 9214 | 16 | |||||
SCXI-1120 SXCI-1120D SCXI-1125 | 8 | Voltage Measurement: PXIe-4300 with TB-4300 (±10V) or TB-4300B (±300V) | 8 | Voltage Measurement:
| 3 | With the exception of the PXIe-4353, all other replacement products offer Channel to Channel Insolation. |
Current Measurement:
| 8 | Current Measurement:
| 4 | |||
Thermocouple Measurement: PXIe-4353 and TB-4353 | 32 | Thermocouple Measurement: NI 9212 | 8 | |||
SCXI-1121 | 4 | Strain/Bridge Measurement: PXIe-4330, PXIe-4331, PXIe-4339 | 8 | NI 9218 | 2 | The SCXI-1121 and SCXI-1122 are universal input modules. To take advantage of measurement specific benefits of PXIe modules choose the module that best suits your sensor needs. C Series does features universal modules. |
Thermocouple Measurement: | 32 | NI 9219 | 4 | |||
RTD Measurement: PXIe-4357 | 20 | |||||
SCXI-1122 | 16 | Strain/Bridge Measurement:
| 8 | NI 9218 | 2 | |
Thermocouple Measurement: | 32 | NI 9219 | 4 | |||
RTD Measurement: PXIe-4357 | 20 | |||||
SCXI-1124 | 6 | Voltage & Current Measurement: PXIe-4322 | 8 | Voltage Measurement: NI 9269 Current Measurement: NI 9265 | 4 | The PXIe-4322 is capable of isolated voltage and current output generation on a per channel basis. The NI 9265 and NI 9266 are channel to earth isolated modules, not channel to channel isolated. |
Current Measurement: NI 9266 | 8 | |||||
SCXI-1126 | 8 | Consider using counters: PXIe-6612 | 8 | Consider using counters: NI 9401 NI 9423 | 8 | The PXIe-6612, NI 9401, NI 9423, or NI 9411 can be suitable replacement depending on the application requirements. Contact NI for any questions about the compatibility. |
Consider using counters: NI 9411 | 6 | |||||
SCXI-1127 | 32 | 32 | None | N/A | Same density in PXI as SCXI | |
SCXI-1129 | 256 | 128 | None | N/A | Topology dependent; PXIe-2737, PXIe-2738, PXIe-2739, PXI-2523B, SwitchBlock | |
SCXI-1130 | 256 | PXI-2530B | 24 | None | N/A | Topology dependent; PXI-2576, PXIe-2575, PXIe-2524, PXIe-2525, PXIe-2526 |
SCXI-1140 | 8 | PXIe-4300 | 8 | NI 9224 | 8 | |
SCXI-1141 SCXI-1142 SCXI-1143 | 8 | Varies: SCXI filtering modules were cascaded with other conditioned measurements to provide additional filtering. Many NI signal conditioning products today have delta sigma ADCs that provide superior anti-aliasing filtering | Replacement depending on the application requirements. Contact NI for any questions about the compatibility. | |||
SCXI-1160 | 16 | PXI-2566 | 16 | None | N/A | |
SCXI-1161 | 8 | PXI-2586 | 10 | None | N/A | Note form of relay (PXI is SPST not SPDT); Also, PXI-2564, PXI-2586 |
SCXI-1162 | 32 | PXI-6509 | 96 | NI 9403 | 32 | PXI variant has 96 non-insolated channels |
PXI-6529 | 48 | |||||
SCXI-1162HV | 32 | PXI-6529 | 48 | NI 9435 | 4 | The PXI-6529 has a maximum input voltage of 60V and 48 channels |
NI 9436 | 8 | |||||
SCXI-1163 | 32 | PXI-6509 | 96 | NI 9476 | 32 | PXI variant has 96 non-insolated channels |
PXI-6513 | 64 | |||||
SCXI-1163R | 32 | PXI-2576 | 64 | None | N/A | Note different relay type and voltage levels; Also, PXI-2534 |
SCXI-1166 | 32 | PXI-2566 | 16 | None | N/A | |
SCXI-1169 | 100 | PXI-2569 | 100 | None | N/A | Same density in PXI as SCXI, same connector |
SCXI-1180 | N/A | None | N/A | None | N/A | |
SCXI-1193 | 32 | 16 | None | N/A | ||
SCXI-1181 | N/A | None | N/A | None | N/A | |
SCXI-1502 | 32 | PXIe-4353 with TB-4353 | 32 | NI 9210 | 4 | |
NI 9213 NI 9214 | 16 | |||||
SCXI-1503 | 16 | RTD Measurement: (PT100) PXIe-4357 | 20 | RTD Measurement: (PT100) NI 9216 (PT1000) NI 9226 | 8 | |
RTD Measurement: (PT100) NI 9217 | 4 | |||||
SCXI-1520 | 8 | Strain/Bridge Measurement: PXIe-4330 PXIe-4331 | 8 | Strain/Bridge Measurement: NI 9237 | 4 | |
SCXI-1521 SCXI-1521B | 24 | Strain/Bridge Measurement: PXIe-4330 PXIe-4331 PXIe-4339 with TB-4339 | 8 | Strain/Bridge Measurement: NI 9235 NI 9236 | 8 | |
SCXI-1530 | 4 | PXIe-4492 | 8 | NI 9234 | 4 | |
SCXI-1531 | 8 | PXIe-4496 PXIe-4498 | 16 | |||
SCXI-1540 | 8 | PXIe-4340 with TB-4340 | 4 | None | N/A | |
SCXI-1581 | 32 | RTD Measurement: (PT100) PXIe-4357 | 20 | RTD Measurement: (PT100) NI 9216 (PT1000) NI 9226 | 8 | The SCXI-1581 is commonly used with the SCXI-1102 for high channel count RTD measurements. The SCXI-1581 was used as an excitation source for these measurements; however, the suggested replacements on PXI and C Series have both the excitation source and measurement capability built into the device. |
SCXI-1600 | 16 | USB-6251 Mass termination USB-6361 Mass termination | 16 | USB CompactDAQ | 4-32 | SCXI-1600 is a USB based DAQ device used to control the SCXI chassis; consider USB-6251, USB-6259, and USB-6361 mass termination devices if you are just replacing this card and not your entire system. Please note that if you're using USB-63xx devices, you must use NI-DAQmx 17.5 or older. CompactDAQ offers chassis with USB connectivity for new systems.
|
USB-6259 Mass termination | 32 | |||||
PXIe-8301 | N/A |
End of Life Products | Replacement Products (if available) | Notes | |
PXI Model Number | PXIe Model Number | C Series Model Number | |
PXI-4204 | PXIe-4300 with TB-4300B PXIe-4310 with TB-4310 (600V) | NI 9228 NI 9229 | The PXIe-4300 and PXIe-4310 (with the associated terminal blocks) have the capable to measure using multiple input ranges. The NI 9228 and the NI 9229 only directly measure up to 60V, if a higher voltage measurement is needed please contact NI. |
PXI-4220 | PXIe-4331 or PXIe-4339 | NI 9237 | |
PXI-4224 | PXIe-4300 with TB-4300 | NI 9224 NI 9239 |
End of Life Products | Replacement Products (if available) | Notes | |
SCXI Model Number | PXI Model Number | C Series Model Number | |
SCXI-1000 | PXIe-1071 | cDAQ 9174 cDAQ 9184 | |
SCXI-1000DC | PXIe-1071 PXIe-1082 (782946-01) | cDAQ 9174 cDAQ 9184 | Choose the PXIe-1071 if the application requires four PXIe slots; however, if DC power is a more important feature choose the PXIe-1082 (DC). |
SCXI-1001 | PXIe-1065 | cDAQ 9178 cDAQ 9188 cDAQ 9179 | The PXIe-1065 features 18 slots and the cDAQ 9179 features 14 slots. |
PXI-1050 | PXIe-1075 | cDAQ 9178 cDAQ 9189 cDAQ 9179 | The PXI-1050 is a combination PXI and SCXI chassis with 8 PXI slots and 4 SCXI slots. The best replacement for this device will be a PXI, PXIe, or CompactDAQ chassis that is capable of housing all required PXI or C Series I/O modules. Some suggested starting points are shown on the left. |
PXI-1052 | PXIe-1075 | cDAQ 9178 cDAQ 9189 cDAQ 9179 | The PXI-1052 is a combination PXI and SCXI chassis with 4 PXI slots and 8 SCXI slots. The best replacement for this device will be a PXI, PXIe, or CompactDAQ chassis that is capable of housing all required PXI or C Series I/O modules. Some suggested starting points are shown on the left. |
End of Life Products | Replacement Products (if available) | Notes | |
Model Number | PXI Model Number(s) | C Series Model Number(s) | |
CA-1000 | Contact NI | Contact NI | |
CA-1000 Accessory | Contact NI | Contact NI | |
SC-2050 | Contact NI | Contact NI | |
SC-2051 | Contact NI | Contact NI | |
SC-2056 | Contact NI | Contact NI | |
SC-2060 | Contact NI | Contact NI | |
SC-2062 | Contact NI | Contact NI | |
SC-2054 | Contact NI | Contact NI | |
SC-2311 | Contact NI | Contact NI | |
SC-2345 | PXI or PXIe Chassis | CompactDAQ Chassis | |
SC-2350 | Contact NI | Contact NI | |
SCC-A10 | PXIe-4300 with TB-4300B | NI 9229 | |
SCC-ACC01 | PXIe-4492 | NI 9218 (2mA) NI 9230 (4mA) NI 9232 (4mA) NI 9234 (2mA) NI 9250 (2mA) | |
SCC-AI01 | PXIe-4300 with TB-4300B PXIe-4304 | NI 9221 | |
SCC-AI02 | PXIe-4330 with TB-4300 PXIe-4304 | NI 9221 | |
SCC-AI03 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9215 | |
SCC-AI04 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9215 | |
SCC-AI05 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9239 | |
SCC-AI06 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9238 | |
SCC-AI07 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9238 | |
SCC-AI13 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9215 | |
SCC-AI14 | PXIe-4302 PXIe-4303 PXIe-4300 with TB-4300 | NI 9215 | |
SCC-AO10 | PXIe-4322 | NI 9269 | |
SCC-CI20 | PXIe-4302 with TB-4302C | NI 9203 NI 9207 NI 9219 NI 9218 with NI 9983 | |
SCC-CO20 | PXIe-4322 PXI-6704 (Legacy) | NI 9265 | |
SCC-CTR01 | PXI-6624 | NI 9422 NI 9435 | |
SCC-DIO1 | PXI-6511 | NI 9423 | |
SCC-DO01 | PXI-6511 | NI 9474 | |
SCC-FT01 | Contact NI | Contact NI | |
SCC-FV01 | PXIe-2461 | Consider using counters: NI 9401 NI 9423 NI 9411 | The PXIe-2461, NI 9401, NI 9423, or NI 9411 can be suitable replacement depending on the application requirements. Contact NI for any questions about the compatibility. |
SCC-LP01 | PXIe-4302 PXIe-4303 | NI 9207 NI 9209 NI 9218 NI 9239 | |
SCC-LP02 | PXIe-4302 PXIe-4303 | NI 9207 NI 9209 NI 9218 NI 9239 | |
SCC-LP03 | PXIe-4302 PXIe-4303 | NI 9207 NI 9209 NI 9218 NI 9239 | |
SCC-LP04 | PXIe-4302 PXIe-4303 | NI 9218 NI 9239 | |
SCC-PWR01 | Contact NI | Contact NI | |
SCC-PWR02 | Contact NI | Contact NI | |
SCC-PWR03 | Contact NI | Contact NI | |
SCC-RLY01 | PXI-2564 | NI 9482 | |
SCC-RTD01 | PXIe-4357 | NI 9217, NI 9219 | |
SCC-SG01 | PXIe-4330 PXIe-4331 PXIe 4339 with TB-4339 | NI 9218 NI 9219 NI 9235 NI 9237 | |
SCC-SG02 | PXIe-4330 PXIe-4331 PXIe 4339 with TB-4339B | NI 9218 NI 9219 NI 9236 NI 9237 | |
SCC-SG03 | PXIe-4330 PXIe-4331 PXIe 4339 with TB-4339 or TB-4339B | NI 9218 NI 9219 NI 9237 | |
SCC-SG04 | PXIe-4330 PXIe-4331 PXIe 4339 with TB-4339 or TB-4339B or TB-4339C | NI 9218 NI 9219 NI 9237 | |
SCC-SG11 | Included with PXIe-4330, PXIe-4331, and PXIe-4339 | Contact NI | |
SCC-SG24 | PXIe-4330 PXIe-4331 PXIe 4339 with TB-4339 or TB-4339B or TB-4339C | NI 9218 NI 9219 NI 9237 | |
SCC-TC01 | PXIe-4353 with TC-4353 | NI 9212 | |
SCC-TC02 | PXIe-4353 with TB-4353 | NI 9210 NI 9212 NI 9213 NI 9214 | |
SSR Backplane | Contact NI | Contact NI |
End of Life Products | Replacement Products (if available) | Notes |
Model Number | PXI Model Number | |
PXI-4462 | PXIe-4464 | |
PXI-4472 | PXIe-4492 | NI-DAQmx driver software required |
End of Life Products | Replacement Products (if available) | Notes |
Model Number | Model Number (PCIe/PXIe) | |
PCI-7332 | None | (1) |
PCI-7334 | None | (1) |
PCI-7342 | None | (1) |
PCI-7344 | None | (1) |
PCI-7352 | None | (1) |
PCI-7354 | None | (1) |
PCI-7356 | None | (1) |
PCI-7358 | None | (1) |
PCI-7390 | None | (1) |
PXI-7332 | None | (1) |
PXI-7334 | None | (1) |
PXI-7342 | None | (1) |
PXI-7344 | None | (1) |
PXI-7352 | None | (1) |
PXI-7354 | None | (1) |
PXI-7356 | None | (1) |
PXI-7358 | None | (1) |
(1) Unfortunately NI does not have a direct replacement for the PXI and PCI motion boards. Please contact NI about other possibilities.
End of Life Products | Replacement Products (if available) | Notes |
Model Number | PXI Model Number | |
PXI-7811R | PXIe-7820 | The PXIe-7820 has 128 digital lines |
PXI-7813R | PXIe-7821 PXIe-7822 | The PXIe-7821 and PXIe-7822 have 128 digital lines |
End of Life Products | Replacement Products (if available) | Notes |
Model Number | Chassis Model Number | |
NI 9144 | NI 9145 |
End of Life Products | Replacement Products (if available) | Notes | |
Model Number | Model Number | C Series Model Number | |
PCI-4351 | PCI-4065 | Thermocouple Measurement: NI 9214 RTD Measurement: NI 9226 | |
USB-1359 | None | None |