Groups

Group members

NameDescription
RFmxSpecAn_NFCfgAveraging

Configures averaging for the noise figure (NF) measurement.

RFmxSpecAn_NFCfgColdSourceDUTSParameters

Configures the scattering parameters of the DUT as a function of the frequency, for use in the cold source measurement method.

RFmxSpecAn_NFCfgColdSourceInputTermination

Configures the characteristics of the microwave termination used as a noise source in the cold source method.

RFmxSpecAn_NFCfgColdSourceMode

Configures the cold source based noise figure (NF) measurement to perform the calibration step or the measurement step.

RFmxSpecAn_NFCfgMeasurementBandwidth

Configures the effective noise-bandwidth in which power measurements are performed in the noise figure (NF) measurement.

RFmxSpecAn_NFCfgMeasurementInterval

Configures the duration for which the signals are acquired at each frequency to perform the noise figure (NF) measurement.

RFmxSpecAn_NFCfgMeasurementMethod

Configures the noise figure (NF) measurement to use either the Y-factor or the cold source method.

RFmxSpecAn_NFCfgYFactorMode

Configures the Y-Factor based noise figure (NF) measurement to perform the calibration step or the measurement step.

RFmxSpecAn_NFCfgYFactorNoiseSourceENR

Configures excess noise ratio (ENR) and temperature of the noise source used by the Y-factor method.

RFmxSpecAn_NFCfgYFactorNoiseSourceLoss

Configures the ohmic loss inherent to the noise source used in the Y-Factor method that is common to the calibration and the measurement steps.

RFmxSpecAn_NFCfgYFactorNoiseSourceSettlingTime

Configures the time required for the acquisition to wait till the noise source used in the Y-Factor method settles to hot or cold state when the noise source is powered on or off.

RFmxSpecAn_NFClearCalibrationDatabase

Clear the noise figure calibration data for Cold Source and Y-Factor method. Calibration data associated with the selected VSA is cleared for the Cold Source method while calibration data associated with the noise source name and the VSA is cleared for the Y-Factor method.

RFmxSpecAn_NFLoadCalibrationLossFromS2p

Loads the ohmic loss data from an S2P file, as a function of frequency of the loss elements between the noise source and the input port of the analyzer during the calibration step, excluding the loss specified as the noise source loss.

RFmxSpecAn_NFLoadColdSourceDUTSParametersFromS2p

Loads the scattering parameter data from an S2P file and configures them as a function of frequency for use in the cold source measurement method.

RFmxSpecAn_NFLoadColdSourceInputTerminationFromS1p

Loads the characteristics of the microwave termination from an S1P file, which used as a noise source in the cold source method.

RFmxSpecAn_NFLoadDUTInputLossFromS2p

Loads the ohmic Input loss data from an S2P file and configures the loss elements between the noise source and the input port of DUT, excluding the losses that are common to the calibration step and the measurement step.

RFmxSpecAn_NFLoadDUTOutputLossFromS2p

Loads the ohmic Output loss data from an S2P file and configures the loss elements between the output port of the DUT and the input port of the analyzer.

RFmxSpecAn_NFLoadExternalPreampGainFromS2p

Loads the gain characteristics of the external preamplifier from an S2P file, as a function of frequency. The gain values are expressed in dB.

RFmxSpecAn_NFLoadYFactorNoiseSourceLossFromS2p

Loads the ohmic loss from an S2P file, which is inherent to the noise source used in the Y-Factor method that is common to the calibration and the measurement steps.

RFmxSpecAn_NFRecommendReferenceLevel

Computes and sets an appropriate reference level based on the expected maximum DUT gain, maximum DUT noise figure, and other measurement and analyzer attributes. You must not set RFMXINSTR_ATTR_MIXER_LEVEL, RFMXINSTR_ATTR_MIXER_LEVEL_OFFSET, RFMXINSTR_ATTR_IF_OUTPUT_POWER_LEVEL_OFFSET, and RFMXINSTR_ATTR_IF_FILTER_BANDWIDTH attributes in order to obtain an appropriate recommended reference level.

RFmxSpecAn_NFValidateCalibrationData

Indicates whether the calibration data is valid for the configuration specified by the signal name in the Selector string parameter.