Interconnecting the Bidirectional MIMO (Baseband and IF) Modules

Complete the following steps to connect the modules of the bidirectional MIMO (baseband and IF) mmWave Transceiver System configuration.

  1. Connect the adjoining PXIe-3610 and PXIe-3620 modules using four MMPX(m)-to-MMPX(m) cables.
    1. Connect the I+ connector of the PXIe-3610 front panel to the TX I+ connector of the PXIe-3620 front panel.
    2. Connect the I– connector of the PXIe-3610 front panel to the TX I– connector of the PXIe-3620 front panel.
    3. Connect the Q+ connector of the PXIe-3610 front panel to the TX Q+ connector of the PXIe-3620 front panel.
    4. Connect the Q– connector of the PXIe-3610 front panel to the TX Q– connector of the PXIe-3620 front panel.
  2. Connect the adjoining PXIe-3620 and PXIe-3630 modules using four MMPX(m)-to-MMPX(m) cables.
    1. Connect the RX I+ connector of the PXIe-3620 front panel to the I+ connector of the PXIe-3630 front panel.
    2. Connect the RX I– connector of the PXIe-3620 front panel to the I– connector of the PXIe-3630 front panel.
    3. Connect the RX Q+ connector of the PXIe-3620 front panel to the Q+ connector of the PXIe-3630 front panel.
    4. Connect the RX Q– connector of the PXIe-3620 front panel to the Q– connector of the PXIe-3630 front panel.
  3. Connect the adjoining PXIe-7902 and PXIe-3610 modules using four Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
    1. Connect the PORT 0 connector of the PXIe-7902 front panel to the 0 connector of the PXIe-3610 front panel.
    2. Connect the PORT 1 connector of the PXIe-7902 front panel to the 1 connector of the PXIe-3610 front panel.
    3. Connect the PORT 2 connector of the PXIe-7902 front panel to the 2 connector of the PXIe-3610 front panel.
    4. Connect the PORT 3 connector of the PXIe-7902 front panel to the 3 connector of the PXIe-3610 front panel.
  4. Connect the adjoining PXIe-3630 and PXIe-7902 modules using four Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
    1. Connect the 0 connector of the PXIe-3630 front panel to the PORT 0 connector of the PXIe-7902 front panel.
    2. Connect the 1 connector of the PXIe-3630 front panel to the PORT 1 connector of the PXIe-7902 front panel.
    3. Connect the 2 connector of the PXIe-3630 front panel to the PORT 2 connector of the PXIe-7902 front panel.
    4. Connect the 3 connector of the PXIe-3630 front panel to the PORT 3 connector of the PXIe-7902 front panel.
    Figure 27. Interconnecting the PXIe-7902, PXIe-3610, PXIe-3620, PXIe-3630, and PXIe-7902 Modules

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
    2. MMPX(m)-to-MMPX(m) Cables
  5. Repeat steps 1 through 4 to connect the second set of adjoining PXIe-7902, PXIe-3610, PXIe-3620, PXIe-3630, and PXIe-7902 modules.
  6. Connect the PXIe-7902 modules in the chassis using three Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) cables.
    1. Connect the PORT 4 connector of the PXIe-7902 front panel in slot 9 of the chassis to the PORT 4 connector of the PXIe-7902 in slot 12 of the chassis.
    2. Connect the PORT 5 connector of the PXIe-7902 front panel in slot 9 of the chassis to the PORT 5 connector of the PXIe-7902 in slot 18 of the chassis.
    3. Connect the PORT 5 connector of the PXIe-7902 front panel in slot 12 of the chassis to the PORT 4 connector of the PXIe-7902 in slot 18 of the chassis.
    Figure 28. Bidirectional MIMO (Baseband and IF) Chassis

    1378

    1. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
    2. MMPX(m)-to-MMPX(m) Cables
    3. Mini-SAS HD(m)-to-Mini-SAS HD(m) (8.25 in.) Cables
  7. Repeat steps 1 through 6 for the second RX/TX chassis.