Remote Panel:Client Release Control
- Updated2026-02-04
- 2 minute(s) read
Returns control of the remote front panel to the server. The server grants control to the next client in the queue or regains control if no requests are in the queue.
This method is similar to the Release Control of VI shortcut menu item.
This method can return networking error codes.
Parameters
| Name | Data type | Required | Description |
|---|---|---|---|
| VI Name | ![]() |
Yes | Name of the VI or project on the server. To specify a VI that is part of a LabVIEW project, you must include the project name, the project library, and the target in the path of the VI, when applicable. For example, if MyVI.vi resides in a project called MyProject.lvproj under target My Computer, enter the VI name as MyProject.lvproj/My Computer/MyVI.vi. If the VI resides in a project library called MyLibrary, also include the project library in the path, as in MyProject.lvproj/My Computer/MyLibrary.lvlib:MyVI.vi. If the VI is not in a project or project library, you can enter the VI name without any additional information. |
| Server Address | ![]() |
Yes | IP address or computer name of the server. |
| Server Port | ![]() |
Yes | Port on which the Web Server is located. |
Remarks
The following table lists the characteristics of this method.
| Short Name | RP.Client Release Control |
| Data type | No return value |
| Available in Run-Time Engine | Yes |
| Available in Real-Time Operating System | Yes |
| Remote access allowed | No |
Examples
Refer to the following example files included with LabVIEW.
- labview\examples\Data Communication\Remote Panels\Remote Panel Methods.lvproj