Defines properties that indicate the output destination of the scan advanced trigger signal.

Derives from

None

Syntax

Namespace: NationalInstruments.ModularInstruments.NISwitch

public class SwitchScanAdvancedOutput

Remarks

For more information, refer to NI Switches Help.

Thread Safety

All members of this type are safe for multithreaded operations.

Properties

NameDescription
External

Gets a value for the external trigger. The switch waits until it receives a trigger from an external source through the external trigger input before processing the next entry in the scan list.

FrontConnector

Gets a value corresponding to the FrontConnector trigger. The switch waits until it receives a trigger on the front connector.

FrontConnectorModule1

Gets a value corresponding to the FrontConnectorModule1 trigger. The switch waits until it receives a trigger on the front connector module 1.

FrontConnectorModule10

Gets a value corresponding to the FrontConnectorModule10 trigger. The switch waits until it receives a trigger on the front connector module 10.

FrontConnectorModule11

Gets a value corresponding to the FrontConnectorModule11 trigger. The switch waits until it receives a trigger on the front connector module 11.

FrontConnectorModule12

Gets a value corresponding to the FrontConnectorModule12 trigger. The switch waits until it receives a trigger on the front connector module 12.

FrontConnectorModule2

Gets a value corresponding to the FrontConnectorModule2 trigger. The switch waits until it receives a trigger on the front connector module 2.

FrontConnectorModule3

Gets a value corresponding to the FrontConnectorModule3 trigger. The switch waits until it receives a trigger on the front connector module 3.

FrontConnectorModule4

Gets a value corresponding to the FrontConnectorModule4 trigger. The switch waits until it receives a trigger on the front connector module 4.

FrontConnectorModule5

Gets a value corresponding to the FrontConnectorModule5 trigger. The switch waits until it receives a trigger on the front connector module 5.

FrontConnectorModule6

Gets a value corresponding to the FrontConnectorModule6 trigger. The switch waits until it receives a trigger on the front connector module 6.

FrontConnectorModule7

Gets a value corresponding to the FrontConnectorModule10 trigger. The switch waits until it receives a trigger on the front connector module 7.

FrontConnectorModule8

Gets a value corresponding to the FrontConnectorModule8 trigger. The switch waits until it receives a trigger on the front connector module 8.

FrontConnectorModule9

Gets a value corresponding to the FrontConnectorModule10 trigger. The switch waits until it receives a trigger on the front connector module 9.

None

Gets a value that indicates no implicit action on scanning connections.

PxiStar

Gets a value corresponding to a trigger on the PXI star trigger bus before processing the next entry in the scan list.

RearConnector

Gets a value corresponding to the RearConnector trigger. The switch waits until it receives a trigger on the rear connector.

RearConnectorModule1

Gets a value corresponding to the RearConnectorModule1 trigger. The switch waits until it receives a trigger on the rear connector module 1.

RearConnectorModule10

Gets a value corresponding to the RearConnectorModule10 trigger.The switch waits until it receives a trigger on the rear connector module 10.

RearConnectorModule11

Gets a value corresponding to the RearConnectorModule11 trigger.The switch waits until it receives a trigger on the rear connector module 11.

RearConnectorModule12

Gets a value corresponding to the RearConnectorModule12 trigger. The switch waits until it receives a trigger on the rear connector module 12.

RearConnectorModule2

Gets a value corresponding to the RearConnectorModule2 trigger.The switch waits until it receives a trigger on the rear connector module 2.

RearConnectorModule3

Gets a value corresponding to the RearConnectorModule3 trigger. The switch waits until it receives a trigger on the rear connector module 3.

RearConnectorModule4

Gets a value corresponding to the RearConnectorModule4 trigger. The switch waits until it receives a trigger on the rear connector module 4.

RearConnectorModule5

Gets a value corresponding to the RearConnectorModule5 trigger. The switch waits until it receives a trigger on the rear connector module 5.

RearConnectorModule6

Gets a value corresponding to the RearConnectorModule6 trigger. The switch waits until it receives a trigger on the rear connector module 6.

RearConnectorModule7

Gets a value corresponding to the RearConnectorModule7 trigger. The switch waits until it receives a trigger on the rear connector module 7.

RearConnectorModule8

Gets a value corresponding to the RearConnectorModule8 trigger. The switch waits until it receives a trigger on the rear connector module 8.

RearConnectorModule9

Gets a value corresponding to the RearConnectorModule9 trigger. The switch waits until it receives a trigger on the rear connector module 9.

Ttl0

Gets a value corresponding to a trigger on the PXI_TRIG0 line. The switch waits until it receives a trigger on the PXI_TRIG0 line before processing the next entry in the scan list.

Ttl1

Gets a value corresponding to a trigger on the PXI_TRIG1 line. The switch waits until it receives a trigger on the PXI_TRIG1 line before processing the next entry in the scan list.

Ttl2

Gets a value corresponding to a trigger on the PXI_TRIG2 line. The switch waits until it receives a trigger on the PXI_TRIG2 line before processing the next entry in the scan list.

Ttl3

Gets a value corresponding to a trigger on the PXI_TRIG3 line. The switch waits until it receives a trigger on the PXI_TRIG3 line before processing the next entry in the scan list.

Ttl4

Gets a value corresponding to a trigger on the PXI_TRIG4 line. The switch waits until it receives a trigger on the PXI_TRIG4 line before processing the next entry in the scan list.

Ttl5

Gets a value corresponding to a trigger on the PXI_TRIG5 line. The switch waits until it receives a trigger on the PXI_TRIG5 line before processing the next entry in the scan list.

Ttl6

Gets a value corresponding to a trigger on the PXI_TRIG6 line. The switch waits until it receives a trigger on the PXI_TRIG6 line before processing the next entry in the scan list.

Ttl7

Gets a value corresponding to a trigger on the PXI_TRIG7 line. The switch waits until it receives a trigger on the PXI_TRIG7 line before processing the next entry in the scan list.