8-Channel Remote Record Configuration Hardware Requirements
- 업데이트 날짜:2024-07-03
- 2분 (읽기 시간)
8-Channel Remote Record Configuration Hardware Requirements
Refer to the following table for the hardware requirements for 8-channel remote record configurations.
| Model | Quantity | Requirements |
|---|---|---|
| PXIe-1095 | 2 | 783882-01 (timing and synchronization upgrade) or 785971-01 |
| PXIe-8881 | 1 | 786636-01 |
| PXIe-8398 | 1 | 784178-01 |
| PXIe-8394 | 1 | 785157-01 |
| PXIe-5841 | 8 | 786982-01 (without the PXIe-5655) or 785832-01 (with the PXIe-5655 if using LO
sharing) This configuration with LO sharing only requires one PXIe-5655. |
| Dell PowerEdge R7525 | 1 | Refer to Data Storage Computer Guidance for the required specifications. |
| PXIe-7903 | 1 | 788917-01 |
| PXIe-6674T | 2 | 781037-01, one per chassis. |
| CDA-2990 | 1 | 784305-01 |
| RF Splitter | 1-2 | This configuration for the instrument frequency range requires either:
|
| SMA to SMA Cable for RF | 9 | Cable length is dependent on system configuration. Refer to RF Cable Guidance. |
| OCuLink x4 Cable to mini-SAS HD | 8 | 786215-01 Ensure that you position the PXIe-5841 and PXIe-7903 in slots to allow for the 1 m cable length. |
| zHD to QSFP28 Cable | 4 | 788928-02 |
| 3M Gen 3 X4 MXI Cable | 1 | 785549-03 |
| SMA to SMA Cable for Clocks and Triggers | 6 | Cable length is dependent on system configuration. Refer to Analog Cable Guidance. |
Refer to the following table for additional hardware requirements to add LO sharing to your remote configurations.
| Model | Quantity | Requirements |
|---|---|---|
| PXIe-5655 | 1 | 786586-01 (if not purchased as part of the PXIe-5841) Add this module as a LO source for star configuration. |
| SCT SC2215 | 1 | 787813-01 Add this module as an amplifier for star configuration of the LO source |
| RF Splitter | 1-2 | The LO source star configuration requires either:
|
| SMA to SMA LO Power Calibration Cable | 8 | Cable length is dependent on system configuration. Refer to Analog Cable
Guidance. LO star configuration sharing requires 8 additional SMA cables. |
| SMA Attenuator | 1 | Refer to SMA Attenuator Guidance for the required specifications. |
| MMPX to SMA Cable | 9 | Cable length is dependent on system configuration. Refer to Analog Cable Guidance. |