Cabling for Multi-Chassis Systems
- 更新日2024-07-03
- 3分で読める
Multi-chassis systems require cabling for MXI, reference clock, and trigger/synchronization connections. Skip this step for 1-, 2-, and 4-channel systems.
| Channel Count | Component | Quantity |
|---|---|---|
| 8 | MXI Controller: PXIe-8398 | 1 |
| MXI Daisy Chain: PXIe-8394 | 1 | |
| Timing Module: PXIe-6674T | 2 | |
| RF IN LO Splitter: ZC2PD-5R263-S+ | 2 | |
| 3M Gen 3 X4 MXI Cable | 1 | |
| SMA-SMA Cable | 12 | |
| 16 | MXI Controller: PXIe-8398 | 2 |
| MXI Daisy Chain: PXIe-8394 | 1 | |
| Timing Module: PXIe-6674T | 3 | |
| Synchronized Signal Distribution Device: CDA-2990 | 1 | |
| 3M Gen 3 X4 MXI Cable | 2 | |
| SMA-SMA Cable | 8 |
Complete the following steps. Refer to the cabling diagrams for more information.
-
Connect the PXIe-8394 module in the master chassis in a star configuration to the
PXIe-9398 modules in the slave chassis with 3M Gen 3 X4 MXI cables, as shown in the
following figures.
Figure 1. Connecting the MXI Modules (8-Channel System)
Figure 1. Connecting the MXI Modules (16-Channel System)
-
Connect the reference clocks:
- For 8-channel systems, connect the PXIe-6674T
modules through a 2-way passive splitter, as shown
in the following figure.
Figure 11. Connecting the Reference Clock Signals (8-Channel System) - For 16-channel systems, connect the PXIe-6674T
modules through the CDA-2990 synchronized signal distribution device, as shown in the
following figure.
Figure 12. Connecting the Reference Clock Signals (≥16-Channel System)
- For 8-channel systems, connect the PXIe-6674T
modules through a 2-way passive splitter, as shown
in the following figure.
-
Connect the PFI (trigger) signals:
- For 8-channel systems, connect the PXIe-6674T
modules through a 2-way passive splitter, as shown
in the following figure.
Figure 13. Connecting the Trigger Signals (8-Channel System) - For 16-channel systems, connect the PXIe-6674T
modules through the CDA-2990 synchronized signal distribution device, as shown in the
following figure.
Figure 14. Connecting the Trigger Signals (≥16-Channel System)
- For 8-channel systems, connect the PXIe-6674T
modules through a 2-way passive splitter, as shown
in the following figure.
関連コンテンツ
- Configuring Multi-Chassis Synchronization
Configure the clock routing and synchronization trigger signal routing between chassis in systems that use two or more PXIe chassis. Skip this process for systems that use a single PXIe chassis.