RFmxSpecAn ACP Configure FFT VI
- Updated2025-10-13
- 3 minute(s) read
Configures window and FFT to obtain a spectrum for the adjacent channel power (ACP) measurement.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default value is "" (empty string). Example: "" "signal::sig1" You can use the RFmxSpecAn Build Signal String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.
FFT Window
—
FFT Window specifies the FFT window type to use to reduce spectral leakage. Refer to the Window and FFT section of the Spectral Measurements topic for more information about FFT window types. The default value is Flat Top.
FFT Padding
—
FFT Padding specifies the factor by which the time-domain waveform is zero-padded before an FFT. The FFT size is given by the following formula: FFT size = waveform size * padding. This parameter is used only when the acquisition span is less than the device instantaneous bandwidth. The default value is -1.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
error out
—
error out contains error information. This output provides standard error out functionality. |