Configures the Reference Clock and the frequency reference source.


icon

Inputs/Outputs

  • cstr.png Selector String

    Selector String specifies a Selector String comprising of the signal name. You do not need to use a selector string, if you want to configure this parameter for all signal instances.

    Example:

    "signal::sig1"

    You can use the personality specific Build String VI to build the selector string.

  • cgenclassrntag.png Instrument Handle In

    Instrument Handle In identifies the instrument session. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI or the RFmxInstr Initialize NIRFSA (Array) VI.

  • cstr.png Frequency Reference Source

    Frequency Reference Source specifies the frequency reference source.

    The default value for PXIe-5840 with PXIe-5653 is RefIn2, else the default value is OnboardClock.

    OnboardClock (OnboardClock)

    PXIe-5663/5663E: RFmx locks the PXIe-5663/5663E to the PXIe-5652 LO source onboard clock. Connect the REF OUT2 connector (if it exists) on the PXIe-5652 to the PXIe-5622 CLK IN terminal. On versions of the PXIe-5663/5663E that lack a REF OUT2 connector on the PXIe-5652, connect the REF IN/OUT connector on the PXIe-5652 to the PXIe-5622 CLK IN terminal.

    PXIe-5665: RFmx locks the PXIe-5665 to the PXIe-5653 LO source onboard clock. Connect the 100 MHz REF OUT terminal on the PXIe-5653 to the PXIe-5622 CLK IN terminal.

    PXIe-5668: Lock the PXIe-5668 to the PXIe-5653 LO SOURCE onboard clock. Connect the LO2 OUT connector on the PXIe-5606 to the CLK IN connector on the PXIe-5624.

    PXIe-5644/5645/5646, PXIe-5820/5840/5841/5842/5860: RFmx locks the device to its onboard clock.

    PXIe-5830/5831/5832: For PXIe-5830, connect the PXIe-5820 REF IN connector to the PXIe-3621 REF OUT connector. For PXIe-5831, connect the PXIe-5820 REF IN connector to the PXIe-3622 REF OUT connector. For PXIe-5832, connect the PXIe-5820 REF IN connector to the PXIe-3623 REF OUT connector.

    PXIe-5831 with PXIe-5653: Connect the PXIe-5820 REF IN connector to the PXIe-3622 REF OUT connector. Connect the PXIe-5653 REF OUT (10 MHz) connector to the PXIe-3622 REF IN connector.

    PXIe-5832 with PXIe-5653: Connect the PXIe-5820 REF IN connector to the PXIe-3623 REF OUT connector. Connect the PXIe-5653 REF OUT (10 MHz) connector to the PXIe-3623 REF IN connector.

    PXIe-5842: Lock to the PXIe-5655 onboard clock. Cables between modules are required as shown in the Getting Started Guide for the instrument.

    PXIe-5860:Lock to the PXIe-5860 onboard clock

    RefIn (RefIn)

    PXIe-5663/5663E: Connect the external signal to the PXIe-5652 REF IN/OUT connector. Connect the REF OUT2 connector (if it exists) on the PXIe-5652 to the PXIe-5622 CLK IN terminal.

    PXIe-5665: Connect the external signal to the PXIe-5653 REF IN connector. Connect the 100 MHz REF OUT terminal on the PXIe-5653 to the PXIe-5622 CLK IN connector. If your external clock signal frequency is set to a frequency other than 10 MHz, set the Frequency Reference Frequency property according to the frequency of your external clock signal.

    PXIe-5668: Connect the external signal to the PXIe-5653 REF IN connector. Connect the LO2 OUT on the PXIe-5606 to the CLK IN connector on the PXIe-5622. If your external clock signal frequency is set to a frequency other than 10 MHz, set the Frequency Reference Frequency property according to the frequency of your external clock signal.

    PXIe-5644/5645/5646, PXIe-5820/5840/5841/5842: RFmx locks the device to the signal at the external REF IN connector.

    PXIe-5830/5831/5832: For PXIe-5830, connect the PXIe-5820 REF IN connector to the PXIe-3621 REF OUT connector. For PXIe-5831, connect the PXIe-5820 REF IN connector to the PXIe-3622 REF OUT connector. For PXIe-5832, connect the PXIe-5820 REF IN connector to the PXIe-3623 REF OUT connector. For PXIe-5830, lock the external signal to the PXIe-3621 REF IN connector. For PXIe-5831, lock the external signal to the PXIe-3622 REF IN connector. For PXIe-5832, lock the external signal to the PXIe-3623 REF IN connector.

    PXIe-5831 with PXIe-5653: Connect the PXIe-5820 REF IN connector to the PXIe-3622 REF OUT connector. Connect the PXIe-5653 REF OUT (10 MHz) connector to the PXIe-3622 REF IN connector. Lock the external signal to the PXIe-5653 REF IN connector.

    PXIe-5832 with PXIe-5653: Connect the PXIe-5820 REF IN connector to the PXIe-3623 REF OUT connector. Connect the PXIe-5653 REF OUT (10 MHz) connector to the PXIe-3623 REF IN connector. Lock the external signal to the PXIe-5653 REF IN connector.

    PXIe-5842: Lock to the signal at the REF IN connector on the associated PXIe-5655. Cables between modules are required as shown in the Getting Started Guide for the instrument.

    PXIe-5860:Lock to the signal at the REF IN connector on the PXIe-5860.

    PXI_Clk (PXI_Clk)

    PXIe-5668: Lock the PXIe-5653 to the PXI backplane clock. Connect the PXIe-5606 LO2 OUT to the LO2 IN connector on the PXIe-5624.

    PXIe-5830/5831/5832/5841 with PXIe-5655/5842: Lock LO module to the PXI backplane clock. Cables between modules are required as shown in the Getting Started Guide for the instrument.

    PXIe-5644/5645/5646, PXIe-5663/5663E/5665, and PXIe-5820/5840/5841/5842/5860: RFmx locks the device to the PXI backplane clock.

    ClkIn (ClkIn)

    PXIe-5663/5663E: RFmx locks the PXIe-5663/5663E to an external 10 MHz signal. Connect the external signal to the PXIe-5622 CLK IN connector, and connect the PXIe-5622 CLK OUT connector to the FREQ REF IN connector on the PXIe-5652.

    PXIe-5665: RFmx locks the PXIe-5665 to an external 100 MHz signal. Connect the external signal to the PXIe-5622 CLK IN connector, and connect the PXIe-5622 CLK OUT connector to the REF IN connector on the PXIe-5653. Set the Frequency Reference Frequency property to 100 MHz.

    PXIe-5668: Lock the PXIe-5668 to an external 100 MHz signal. Connect the external signal to the CLK IN connector on the PXIe-5624, and connect the PXIe-5624 CLK OUT connector to the REF IN connector on the PXIe-5653. Set the Frequency Reference Frequency property to 100 MHz.

    PXIe-5644/5645/5646, PXIe-5820/5830/5831/5831 with PXIe-5653/5832/5832 with PXIe-5653/5840/5841/5842/5860: This configuration does not apply.

    RefIn2 (RefIn2)

    Configure open NI-RFSG sessions to the device to use RefIn for the PXIe-5840 or OnboardClock for the PXIe-5840 with PXIe-5653.

    PXIe-5663/5663E/5665/5668, PXIe-5644/5645/5646, and PXIe-5820/5830/5831/5831 with PXIe-5653/5832/5832 with PXIe-5653/5840/5841/5842/5860: This configuration does not apply.

    PXI_ClkMaster (PXI_ClkMaster)

    PXIe-5831 with PXIe-5653: RFmx configures the PXIe-5653 to export the reference clock and configures the PXIe-5820 and PXIe-3622 to use PXI_Clk as the reference clock source. You must connect the PXIe-5653 REF OUT (10 MHz) connector to the PXI chassis REF IN connector.

    PXIe-5832 with PXIe-5653: RFmx configures the PXIe-5653 to export the reference clock and configures the PXIe-5820 and PXIe-3623 to use PXI_Clk as the reference clock source. You must connect the PXIe-5653 REF OUT (10 MHz) connector to the PXI chassis REF IN connector.

    PXIe-5663/5663E/5665/5668, PXIe-5644/5645/5646, PXIe-5820/5830/5831/5832/5840/5841/5842/5860: This configuration does not apply.

  • cdbl.png Frequency (Hz)

    Frequency specifies the Reference Clock rate when the Frequency Reference Source parameter is set to ClkIn or RefIn. This value is expressed in Hz.

    The default value is 10 MHz.

  • cerrcodeclst.png error in (no error)

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • igenclassrntag.png Instrument Handle Out

    Instrument Handle Out passes a reference of the instrument session to the next VI.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.