Specifies the method to use to notify another instrument that all signals through the switch module have settled following the processing of one entry in the scan list.

Related topics

Remarks

The following table lists the characteristics of this property.

Short Name Scan Advanced Output
Data type ci32.png
Permissions Read/Write
Channel-based No
Resettable No
NONE 0

The switch module does not produce a Scan Advanced Output trigger.

EXTERNAL 2

The switch module produces the Scan Advanced Output trigger on the external trigger output.

PXI_Trig0 111

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig0 line before processing the next entry in the scan list.

PXI_Trig1 112

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig1 line before processing the next entry in the scan list.

PXI_Trig2 113

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig2 line before processing the next entry in the scan list.

PXI_Trig3 114

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig3 line before processing the next entry in the scan list.

PXI_Trig4 115

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig4 line before processing the next entry in the scan list.

PXI_Trig5 116

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig5 line before processing the next entry in the scan list.

PXI_Trig6 117

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig6 line before processing the next entry in the scan list.

PXI_Trig7 118

The switch module produces the Scan Advanced Output Trigger on the PXI_Trig7 line before processing the next entry in the scan list.

PXI_STAR 125

The switch module produces the Scan Advanced Output Trigger on the PXI Star trigger bus before processing the next entry in the scan list.

REARCONNECTOR 1000

The switch module produces the Scan Advanced Output Trigger on the rear connector.

REARCONNECTOR_MODULE1 1021

The switch module produces the Scan Advanced Output Trigger on the rear connector module 1.

REARCONNECTOR_MODULE2 1022

The switch module produces the Scan Advanced Output Trigger on the rear connector module 2.

REARCONNECTOR_MODULE3 1023

The switch module produces the Scan Advanced Output Trigger on the rear connector module 3.

REARCONNECTOR_MODULE4 1024

The switch module produces the Scan Advanced Output Trigger on the rear connector module 4.

REARCONNECTOR_MODULE5 1025

The switch module produces the Scan Advanced Output Trigger on the rear connector module 5.

REARCONNECTOR_MODULE6 1026

The switch module produces the Scan Advanced Output Trigger on the rear connector module 6.

REARCONNECTOR_MODULE7 1027

The switch module produces the Scan Advanced Output Trigger on the rear connector module 7.

REARCONNECTOR_MODULE8 1028

The switch module produces the Scan Advanced Output Trigger on the rear connector module 8.

REARCONNECTOR_MODULE9 1029

The switch module produces the Scan Advanced Ouptut Trigger on the rear connector module 9.

REARCONNECTOR_MODULE10 1030

The switch module produces the Scan Advanced Output Trigger on the rear connector module 10.

REARCONNECTOR_MODULE11 1031

The switch module produces the Scan Advanced Output Trigger on the rear connector module 11.

REARCONNECTOR_MODULE12 1032

The switch module produces the Scan Advanced Output Trigger on the rear connector module 12.

FRONTCONNECTOR 1001

The switch module produces the Scan Advanced Output Trigger on the front connector.

FRONTCONNECTOR_MODULE1 1041

The switch module produces the Scan Advanced Output Trigger on the front connector module 1.

FRONTCONNECTOR_MODULE2 1042

The switch module produces the Scan Advanced Output Trigger on the front connector module 2.

FRONTCONNECTOR_MODULE3 1043

The switch module produces the Scan Advanced Output Trigger on the front connector module 3.

FRONTCONNECTOR_MODULE4 1044

The switch module produces the Scan Advanced Output Trigger on the front connector module 4.

FRONTCONNECTOR_MODULE5 1045

The switch module produces the Scan Advanced Output Trigger on the front connector module 5.

FRONTCONNECTOR_MODULE6 1046

The switch module produces the Scan Advanced Output Trigger on the front connector module 6.

FRONTCONNECTOR_MODULE7 1047

The switch module produces the Scan Advanced Output Trigger on the front connector module 7.

FRONTCONNECTOR_MODULE8 1048

The switch module produces the Scan Advanced Output Trigger on the front connector module 8.

FRONTCONNECTOR_MODULE9 1049

The switch module produces the Scan Advanced Output Trigger on the front connector module 9.

FRONTCONNECTOR_MODULE10 1050

The switch module produces the Scan Advanced Output Trigger on the front connector module 10.

FRONTCONNECTOR_MODULE11 1051

The switch module produces the Scan Advanced Output Trigger on the front connector module 11.

FRONTCONNECTOR_MODULE12 1052

The switch module produces the Scan Advanced Output Trigger on the front connector module 12.