Interface:Ethernet:Time Sync:Port:Log Sync Interval
- Updated2024-07-10
- 1 minute(s) read
If Port State is Master, this property provides the current interval used for successive transmits of the Sync message by this port.
Remarks
The following table lists the characteristics of this property.
Short Name | Intf.Enet.Time.Port.SyncIntvl |
Data type | ![]() |
Permissions | Read Only |
125 milliseconds | -3 | |
250 milliseconds | -2 | |
500 milliseconds | -1 | |
1 second | 0 | |
2 seconds | 1 |