GPRF RFSA SCPI Command Reference

SCPI command reference for the GPRF signal analyzer instrument personality.

CONFigure:RFSA:GPRF<i>:EATTenuation


        Usage:
        CONFigure:RFSA:GPRF<i>:EATTenuation[?] <ExternalAttenuation>
Query Response:
        <ExternalAttenuation>
      

Description

Specifies the external attenuation. External attenuation is applied on top of any attenuation provided for the specified port.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <ExternalAttenuation>

Description

External attenuation value.

Datatype

Double

Default Value

0.00

Range

[-100.00:100.00]

Unit

dB

CONFigure:RFSA:GPRF<i>:FREQuency[:CENTer]


        Usage:
        CONFigure:RFSA:GPRF<i>:FREQuency[:CENTer][?] <CenterFrequency>
Query Response:
        <CenterFrequency>
      

Description

Specifies the center frequency.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <CenterFrequency>

Description

Center frequency of the received signal.

Datatype

Double

Default Value

1.000000000000000E+009

Range

[6.500000000000000E+007:6.000000000000000E+009]

Unit

Hz

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt[:ENABle]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt[:ENABle][?] <FcountEnabled>
Query Response:
        <FcountEnabled>
      

Description

Specifies whether to enable frequency count measurement for non-sequence mode.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountEnabled>

Description

0 | OFF: Disables the frequency count measurement.
            1 | ON:  Enables the frequency count measurement.

Datatype

Boolean

Default Value

0

Range

0 | 1 | OFF | ON | FALSE |

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:AVERaging[:COUNt]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:AVERaging[:COUNt][?] <FcountNumberOfAverages>
Query Response:
        <FcountNumberOfAverages>
      

Description

Specifies the number of averages to use for the frequency count measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountNumberOfAverages>

Description

Number of signal averages to use for the frequency count measurement.

Datatype

Integer32

Default Value

1

Range

[1:10000]

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:AVERaging:TYPE


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:AVERaging:TYPE[?] <FcountAverageType>
Query Response:
        <FcountAverageType>
      

Description

Specifies the averaging type for the frequency count measurement. The averaged instantaneous signal phase difference is used for the measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountAverageType>

Description

MEAN: Uses the mean of the instantaneous signal phase difference over multiple acquisitions for the frequency measurement.
            MAX: Uses the maximum instantaneous signal phase difference over multiple acquisitions for the frequency measurement.
            MIN: Uses the minimum instantaneous signal phase difference over multiple acquisitions for the frequency measurement.
            MAXMIN: Uses the maximum instantaneous signal phase difference over multiple acquisitions for the frequency measurement. The sign of the phase difference is ignored to find the maximum instantaneous value.

Datatype

Enumeration

Default Value

MEAN

Range

MEAN | MAX | MIN | MAXMIN

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:INTerval


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:INTerval[?] <FcountMeasurementInterval>
Query Response:
        <FcountMeasurementInterval>
      

Description

Specifies the interval for the frequency count measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountMeasurementInterval>

Description

Interval for the frequency count measurement.

Datatype

Double

Default Value

1.000000000000000E-003

Range

[1.000000000000000E-006:1.000000000000000E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth[?] <FcountResolutionBandwidth>
Query Response:
        <FcountResolutionBandwidth>
      

Description

Specifies the bandwidth of the resolution bandwidth (RBW) filter used for the frequency count measurement.
FCOunt is computed from a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountResolutionBandwidth>

Description

RBW filter bandwidth.

Datatype

Double

Default Value

1.000000000000000E+003

Range

[1.000000000000000E+003:5.000000000000000E+007]

Unit

Hz

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth:FILTer[:TYPE]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth:FILTer[:TYPE][?] <FcountRbwFilterType>
Query Response:
        <FcountRbwFilterType>
      

Description

Specifies the shape of the digital resolution bandwidth (RBW) filter used for the frequency count measurement.
FCOunt is computed from a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountRbwFilterType>

Description

NONE: The measurement does not use any RBW filtering.
            GAUSSIAN: The RBW filter has a Gaussian response.
            FLAT: The RBW filter has a flat response.
            ST4: The RBW filter has a response of a 4-pole synchronously-tuned filter.
            ST5: The RBW filter has a response of a 5-pole synchronously-tuned filter.
            RRC: The RRC filter uses the roll-off factor specified by the alpha value.

Datatype

Enumeration

Default Value

GAUSSIAN

Range

NONE | GAUSSIAN | FLAT | ST4 | ST5 | RRC

CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth:FILTer:ALPHa


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:FCOunt:RBWidth:FILTer:ALPHa[?] <FcountRbwFilterAlpha>
Query Response:
        <FcountRbwFilterAlpha>
      

Description

Specifies the roll-off factor of the root-raised cosine (RRC) filter used for the frequency count measurement.
FCOunt is computed from a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountRbwFilterAlpha>

Description

RRC filter roll-off factor. This value is used when the corresponding filter type is set to RRC.

Datatype

Double

Default Value

0.01

Range

[0.00:1.00]

CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime[:ENABle]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime[:ENABle][?] <IqvtEnabled>
Query Response:
        <IqvtEnabled>
      

Description

Specifies whether to enable I/Q versus time (IQVT) measurement for non-sequence mode.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtEnabled>

Description

0 | OFF: Disables the IQVT measurement.
            1 | ON:  Enables the IQVT measurement.

Datatype

Boolean

Default Value

0

Range

0 | 1 | OFF | ON | FALSE |

CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:INTerval


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:INTerval[?] <IqvtMeasurementInterval>
Query Response:
        <IqvtMeasurementInterval>
      

Description

Specifies the measurement interval for the I/Q versus time (IQVT) measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtMeasurementInterval>

Description

Interval for the IQVT measurement. The measurement is performed for the specified interval, which is recommended, but not required, to be less than the slot duration.

Datatype

Double

Default Value

1.000000000000000E-003

Range

[1.000000000000000E-006:1.000000000000000E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth[?] <IqvtResolutionBandwidth>
Query Response:
        <IqvtResolutionBandwidth>
      

Description

Specifies the bandwidth of the resolution bandwidth (RBW) filter used for the I/Q versus time (IQVT) measurement.
This measurement is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtResolutionBandwidth>

Description

RBW filter bandwidth.

Datatype

Double

Default Value

1.000000000000000E+003

Range

[1.000000000000000E+003:5.000000000000000E+007]

Unit

Hz

CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth:FILTer[:TYPE]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth:FILTer[:TYPE][?] <IqvtRbwFilterType>
Query Response:
        <IqvtRbwFilterType>
      

Description

Specifies the shape of the digital resolution bandwidth (RBW) filter used for the I/Q versus time (IQVT) measurement.
This measurement is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtRbwFilterType>

Description

NONE: The measurement does not use any RBW filtering.
            GAUSSIAN: The RBW filter has a Gaussian response.
            FLAT: The RBW filter has a flat response.
            ST4: The RBW filter has a response of a 4-pole synchronously-tuned filter.
            ST5: The RBW filter has a response of a 5-pole synchronously-tuned filter.
            RRC: The RRC filter uses the roll-off factor specified by the alpha value.

Datatype

Enumeration

Default Value

GAUSSIAN

Range

NONE | GAUSSIAN | FLAT | ST4 | ST5 | RRC

CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth:FILTer:ALPHa


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:IQVTime:RBWidth:FILTer:ALPHa[?] <IqvtRbwFilterAlpha>
Query Response:
        <IqvtRbwFilterAlpha>
      

Description

Specifies the roll-off factor of the root-raised cosine (RRC) filter used for the I/Q versus time (IQVT) measurement.
This measurement is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtRbwFilterAlpha>

Description

RRC filter roll-off factor. This value is used when the corresponding filter type is set to RRC.

Datatype

Double

Default Value

0.01

Range

[0.00:1.00]

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower[:ENABle]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower[:ENABle][?] <TxpEnabled>
Query Response:
        <TxpEnabled>
      

Description

Specifies whether to enable transmit power (TXP) measurement for non-sequence mode.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpEnabled>

Description

0 | OFF: Disables the TXP measurement.
            1 | ON: Enables the TXP measurement.

Datatype

Boolean

Default Value

1

Range

0 | 1 | OFF | ON | FALSE |

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:AVERaging[:COUNt]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:AVERaging[:COUNt][?] <TxpNumberOfAverages>
Query Response:
        <TxpNumberOfAverages>
      

Description

Specifies the number of averages for the transmit power (TXP) measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpNumberOfAverages>

Description

Number of signal averages to use for the TXP measurement.

Datatype

Integer32

Default Value

1

Range

[1:10000]

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:AVERaging:TYPE


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:AVERaging:TYPE[?] <TxpTypeofAveraging>
Query Response:
        <TxpTypeofAveraging>
      

Description

Specifies the averaging type for the transmit power (TXP) measurement. The averaged power trace is used for the measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpTypeofAveraging>

Description

MEAN: Uses the mean of the instantaneous power in the power trace over multiple acquisitions for the TXP measurement.
            MAX: Uses the maximum instantaneous power in the power trace over multiple acquisitions for the TXP measurement.
            MIN: Uses the minimum instantaneous power in the power trace over multiple acquisitions for the TXP measurement.
            MAXMIN: Uses the maximum instantaneous power in the power trace over multiple acquisitions for the TXP measurement. The sign of the power is ignored to find the maximum instantaneous value. (Not supported at this point)

Datatype

Enumeration

Default Value

MEAN

Range

MEAN | MAX | MIN | MAXMIN

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:INTerval


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:INTerval[?] <TxpMeasurementInterval>
Query Response:
        <TxpMeasurementInterval>
      

Description

Specifies the measurement interval for the transmit power (TXP) measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpMeasurementInterval>

Description

Interval for the TXP measurement.

Datatype

Double

Default Value

1.000000000000000E-003

Range

[1.000000000000000E-006:1.000000000000000E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth[?] <TxpResolutionBandwidth>
Query Response:
        <TxpResolutionBandwidth>
      

Description

Specifies the bandwidth of the transmit power (TXP) filter used for the frequency count measurement.
TxP is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpResolutionBandwidth>

Description

RBW filter bandwidth.

Datatype

Double

Default Value

1.000000000000000E+006

Range

[1.000000000000000E+003:2.000000000000000E+008]

Unit

Hz

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth:FILTer[:TYPE]


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth:FILTer[:TYPE][?] <TxpRbwFilterType>
Query Response:
        <TxpRbwFilterType>
      

Description

Specifies the shape of the digital resolution bandwidth (RBW) filter.
TxP is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpRbwFilterType>

Description

NONE: The measurement does not use any RBW filtering.
            GAUSSIAN: The RBW filter has a Gaussian response.
            FLAT: The RBW filter has a flat response.
            ST4: The RBW filter has a response of a 4-pole synchronously-tuned filter.
            ST5: The RBW filter has a response of a 5-pole synchronously-tuned filter.
            RRC: The RRC filter uses the roll-off factor specified by the alpha value.

Datatype

Enumeration

Default Value

GAUSSIAN

Range

NONE | GAUSSIAN | FLAT | ST4 | ST5 | RRC

CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth:FILTer:ALPHa


        Usage:
        CONFigure:RFSA:GPRF<i>:MEASurement:TXPower:RBWidth:FILTer:ALPHa[?] <TxpRbwFilterAlpha>
Query Response:
        <TxpRbwFilterAlpha>
      

Description

Specifies the roll-off factor of the root-raised cosine (RRC) filter used for the transmit power (TXP) measurement.
TxP is a zero span measurement of transmitted power using the time-domain signal as seen through a resolution bandwidth filter for the specified measurement interfal. For this reason RBW = measurement BW

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpRbwFilterAlpha>

Description

RRC filter roll-off factor. This value is used when the corresponding filter type is set to RRC.

Datatype

Double

Default Value

0.01

Range

[0.00:1.00]

CONFigure:RFSA:GPRF<i>:PORTname


        Usage:
        CONFigure:RFSA:GPRF<i>:PORTname[?] <PortName>
Query Response:
        <PortName>
      

Description

Specifies the port name of the instrument used to acquire the signal.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <PortName>

Description

When initiated, the signal is acquired from the port specified by PORTname. The signal is adjusted for any attenuation table assigned to that port.

Datatype

String

Default Value

"Port0"

CONFigure:RFSA:GPRF<i>:POWer[:MAXimum]


        Usage:
        CONFigure:RFSA:GPRF<i>:POWer[:MAXimum][?] <MaximumInputPower>
Query Response:
        <MaximumInputPower>
      

Description

Specifies the maximum expected input power level at the input port.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <MaximumInputPower>

Description

Maximum expected input power to the instrument.

Datatype

Double

Default Value

0.00

Range

[-174.00:50.00]

Unit

dBm

CONFigure:RFSA:GPRF<i>:POWer:AUTO


        Usage:
        CONFigure:RFSA:GPRF<i>:POWer:AUTO[?] <AutoLevelEnabled>
Query Response:
        <AutoLevelEnabled>
      

Description

Specifies the mode used to determine the level of the maximum input power. Auto power takes additional time to execute because it requires additional signal acquisition for the instrument to evaluate the signal strength of the applied signal.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <AutoLevelEnabled>

Description

0 | OFF: Disables automatic setting of the maximum input power.
            1 | ON: Enables automatic setting of the maximum input power.

Datatype

Boolean

Default Value

0

Range

0 | 1 | FALSE | TRUE | OFF | ON

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:FCOunt:ENABle[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:FCOunt:ENABle[:ALL][?] <FcountEnable[n]>
Query Response:
        <FcountEnable[n]>
      

Description

Specifies whether to enable frequency count measurements for all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountEnable[n]>

Description

Enables or disables frequency count measurements for all segments of the sequence. The size of the array depends on the currently defined number of segments.
            0 | OFF: Disables the frequency count measurement.
            1 | ON: Enables the frequency count measurement.

Datatype

Boolean

Default Value

0

Range

0 | 1 | ON | OFF

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:FCOunt:INTerval[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:FCOunt:INTerval[:ALL][?] <FcountMeasurementInterval[n]>
Query Response:
        <FcountMeasurementInterval[n]>
      

Description

Specifies the interval for the frequency count measurement of all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountMeasurementInterval[n]>

Description

Interval for the frequency count measurement. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:IQVTime:ENABle[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:IQVTime:ENABle[:ALL][?] <IqvtEnable[n]>
Query Response:
        <IqvtEnable[n]>
      

Description

Specifies whether to enable I/Q versus time (IQVT) measurements for all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtEnable[n]>

Description

Enables or disables IQVT measurements for all segments of the sequence. The size of the array depends on the currently defined number of segments.
            0 | OFF: Disables the IQVT measurement.
            1 | ON: Enables the IQVT measurement.

Datatype

Boolean

Default Value

0

Range

0 | 1 | ON | OFF

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:IQVTime:INTerval[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:IQVTime:INTerval[:ALL][?] <IqvtMeasurementInterval[n]>
Query Response:
        <IqvtMeasurementInterval[n]>
      

Description

Specifies the measurement interval for the I/Q versus time (IQVT) measurement of all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <IqvtMeasurementInterval[n]>

Description

Interval for the IQVT measurement. The measurement is performed for the specified interval, which is recommended, but not required, to be less than slot duration. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:TXPower:ENABle[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:TXPower:ENABle[:ALL][?] <TxpEnable[n]>
Query Response:
        <TxpEnable[n]>
      

Description

Specifies whether to enable transmit power (TXP) measurements for all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpEnable[n]>

Description

Enables or disables TXP measurements for all segments of the sequence. The size of the array depends on the currently defined number of segments.
            0 | OFF: Disables the TXP measurement.
            1 | ON: Enables the TXP measurement.

Datatype

Boolean

Default Value

0

Range

0 | 1 | ON | OFF

CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:TXPower:INTerval[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence[:MEASurement]:TXPower:INTerval[:ALL][?] <TxpMeasurementInterval[n]>
Query Response:
        <TxpMeasurementInterval[n]>
      

Description

Specifies the measurement interval for the transmit power (TXP) measurement.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TxpMeasurementInterval[n]>

Description

Interval for the TXP measurement. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:DURation[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:DURation[:ALL][?] <SegmentDuration[n]>
Query Response:
        <SegmentDuration[n]>
      

Description

Specifies the duration elements for all defined segments in the sequence.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SegmentDuration[n]>

Description

Duration of each segment of the sequence. The size of the array depends on the currently defined number of segments.
            Each <SegmentDuration> element must be greater than <SlotCount> x <SlotDuration> for the corresponding segments.

Datatype

Double

Default Value

1.00E-002

Range

[5.00E-005:3.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:EATTenuation[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:EATTenuation[:ALL][?] <ExternalAttenuation[n]>
Query Response:
        <ExternalAttenuation[n]>
      

Description

Specifies the external attenuation for all segments in the sequence. External attenuation is applied on top of any attenuation provided for the specified port.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <ExternalAttenuation[n]>

Description

External attenuation value. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

0.00

Range

[-100.00:100.00]

Unit

dB

CONFigure:RFSA:GPRF<i>:SEQuence:ENABle


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:ENABle[?] <SequenceEnable>
Query Response:
        <SequenceEnable>
      

Description

Specifies whether to enable sequence mode. A sequence comprises one or more segments. A segment comprises one or more measurements.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SequenceEnable>

Description

0 | OFF: Disables sequence mode.
            1 | ON: Enables sequence mode.

Datatype

Boolean

Default Value

0

Range

0 | 1 | ON | OFF

CONFigure:RFSA:GPRF<i>:SEQuence:FREQuency[:CENTer][:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:FREQuency[:CENTer][:ALL][?] <SegmentCenterFrequency[n]>
Query Response:
        <SegmentCenterFrequency[n]>
      

Description

Specifies the center frequency for all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SegmentCenterFrequency[n]>

Description

Center frequency of the received signal per segment. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

1.000000000000000E+009

Range

[6.500000000000000E+007:6.600000000000000E+009]

Unit

Hz

CONFigure:RFSA:GPRF<i>:SEQuence:NSEGments


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:NSEGments[?] <NumberOfSegments>
Query Response:
        <NumberOfSegments>
      

Description

Specifies the number of segments in a sequence. You must set this parameter before setting other sequence-based instrument or measurement parameters.

Availability

Command/Query

Execution Mode

Command: Sequential
Query: Overlapped

Parameter: <NumberOfSegments>

Description

Number of segments in a sequence.

Datatype

Integer32

Default Value

1

Range

[0:10000]

CONFigure:RFSA:GPRF<i>:SEQuence:POWer[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:POWer[:ALL][?] <MaxInputPower[n]>
Query Response:
        <MaxInputPower[n]>
      

Description

Specifies the maximum expected input power at the specified input port for all segments in the sequence.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <MaxInputPower[n]>

Description

Maximum expected input power per segment. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

0.00

Range

[-174.00:50.00]

Unit

dBm

CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>[:SETup]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>[:SETup][?] <SegmentCenterFrequency>,<SegmentDuration>,<MaxInputPower>,<ExternalAttenuation>,<SlotCount>,<SlotDuration>,<SlotOffset>
Query Response:
        <SegmentCenterFrequency>,<SegmentDuration>,<MaxInputPower>,<ExternalAttenuation>,<SlotCount>,<SlotDuration>,<SlotOffset>
      

Description

Specifies all physical properties of a signal for a given segment.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SegmentCenterFrequency>

Description

Center frequency of the received signal.

Datatype

Double

Default Value

1.000000000000000E+009

Range

[6.500000000000000E+007:6.600000000000000E+009]

Unit

Hz

Parameter: <SegmentDuration>

Description

Segment duration. <SegmentDuration> must be greater than the corresponding <SlotCount> x <SlotDuration>.

Datatype

Double

Default Value

1.00E-002

Range

[5.00E-005:3.00E+001]

Unit

sec

Parameter: <MaxInputPower>

Description

Maximum expected input power to the instrument.

Datatype

Double

Default Value

0.00

Range

[-174.00:50.00]

Unit

dBm

Parameter: <ExternalAttenuation>

Description

External attenuation value.

Datatype

Double

Default Value

0.00

Range

[-100.00:100.00]

Unit

dB

Parameter: <SlotCount>

Description

Number of segment slots.

Datatype

Integer32

Default Value

1

Range

[1:10000]

Parameter: <SlotDuration>

Description

Duration of each segment slot.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

Parameter: <SlotOffset>

Description

Offset from the start of the segment until the measurement interval begins.

Datatype

Double

Default Value

0.00E+000

Range

[0.00E+000:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>:MEASurement:ENABle[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>:MEASurement:ENABle[:ALL][?] <FCOuntEnable>,<IQVTimeEnable>,<TXPowerEnable>
Query Response:
        <FCOuntEnable>,<IQVTimeEnable>,<TXPowerEnable>
      

Description

Specifies which measurements to enable for a given segment.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FCOuntEnable>

Description

0 | OFF: Disables the frequency counter measurement.
            1 | ON: Enables the frequency counter measurement.

Datatype

Boolean

Default Value

1

Range

0 | 1 | ON | OFF

Parameter: <IQVTimeEnable>

Description

0 | OFF: Disables the I/Q versus time (IQVT) measurement.
            1 | ON: Enables the I/Q versus time (IQVT) measurement.

Datatype

Boolean

Default Value

1

Range

0 | 1 | ON | OFF

Parameter: <TXPowerEnable>

Description

0 | OFF: Disables the transmit power (TXP) measurement.
            1 | ON: Enables the transmit power (TXP) measurement.

Datatype

Boolean

Default Value

1

Range

0 | 1 | ON | OFF

CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>:MEASurement:INTerval[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SEGMent<i>:MEASurement:INTerval[:ALL][?] <FcountMeasurementInterval>,<IqvtimeMeasurementInterval>,<TxpowerMeasurementInterval>
Query Response:
        <FcountMeasurementInterval>,<IqvtimeMeasurementInterval>,<TxpowerMeasurementInterval>
      

Description

Specifies the interval for all measurements of a given segment.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <FcountMeasurementInterval>

Description

Interval for the frequency count measurement.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

Parameter: <IqvtimeMeasurementInterval>

Description

Interval for the I/Q versus time (IQVT) measurement.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

Parameter: <TxpowerMeasurementInterval>

Description

Interval for the transmit power (TXP) measurement.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:SLOT[:COUNt][:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SLOT[:COUNt][:ALL][?] <SlotCount[n]>
Query Response:
        <SlotCount[n]>
      

Description

Specifies the number of slots for all segments.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SlotCount[n]>

Description

Number of segment slots. The size of the array depends on the currently defined number of segments.

Datatype

Integer32

Default Value

1

Range

[1:10000]

CONFigure:RFSA:GPRF<i>:SEQuence:SLOT:DURation[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SLOT:DURation[:ALL][?] <SlotDuration[n]>
Query Response:
        <SlotDuration[n]>
      

Description

Specifies the slot duration for all segments in the sequence.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SlotDuration[n]>

Description

Duration of each segment slot. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

1.00E-003

Range

[1.00E-006:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:SLOT:OFFSet[:ALL]


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:SLOT:OFFSet[:ALL][?] <SlotOffset[n]>
Query Response:
        <SlotOffset[n]>
      

Description

Specifies the sequence offset for all segments in the sequence.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <SlotOffset[n]>

Description

Offset from the start of the segment until the measurement interval begins. The size of the array depends on the currently defined number of segments.

Datatype

Double

Default Value

0.00E+000

Range

[0.00E+000:1.00E+001]

Unit

sec

CONFigure:RFSA:GPRF<i>:SEQuence:TRIGger


        Usage:
        CONFigure:RFSA:GPRF<i>:SEQuence:TRIGger[?] <TriggerMode>
Query Response:
        <TriggerMode>
      

Description

Availability

Command/Query

Execution Mode

Command: Sequential
Query: Sequential

Parameter: <TriggerMode>

Description

Sequence triggering mode.
            First: Only triggers on the first segment.
            Every: Triggers on every segment.

Datatype

Enumeration

Default Value

FIRST

Range

FIRST | EVERY

CONFigure:RFSA:GPRF<i>:TRACe[:ENABle]


        Usage:
        CONFigure:RFSA:GPRF<i>:TRACe[:ENABle][?] <GprfTraceEnabled>
Query Response:
        <GprfTraceEnabled>
      

Description

Specifies whether to enable collection of trace data for general purpose RF measurements.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <GprfTraceEnabled>

Description

If disabled, no trace data is collected so no traces are fetched.
            0 | OFF: Disables collection of trace data.
            1 | ON: Enables collection of trace data.

Datatype

Boolean

Default Value

0

Range

0 | 1 | FALSE | TRUE | OFF | ON

FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt[:ALL]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt[:ALL]?
Query Response:
        <AverageMeanFrequency>,<MeanPhase>
      

Description

Fetches the frequency counter measurement results.

Availability

Query

Execution Mode

Overlapped

Parameter: <AverageMeanFrequency>

Description

Average mean frequency evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

Hz

Parameter: <MeanPhase>

Description

Mean phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt:FREQuency[:AVERage]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt:FREQuency[:AVERage]?
Query Response:
        <AverageMeanFrequencyError>
      

Description

Fetches the frequency counter frequency error results.

Availability

Query

Execution Mode

Overlapped

Parameter: <AverageMeanFrequencyError>

Description

Average mean frequency error evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt:PHASe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:FCOunt:PHASe?
Query Response:
        <MeanPhase>
      

Description

Fetches the frequency counter phase results.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPhase>

Description

Mean phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime[:ALL]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime[:ALL]?
Query Response:
        <MeanPower>,<MeanPhase>,<MeandPhase>,<MeanFrequencyError>
      

Description

Fetches the I/Q versus time (IQVT) results.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPower>

Description

Mean power evaluated over the specified interval.

Datatype

Double

Unit

dBm

Parameter: <MeanPhase>

Description

Mean phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

Parameter: <MeandPhase>

Description

Mean delta phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

Parameter: <MeanFrequencyError>

Description

Mean frequency error evaluated over the specified interval and compared to the expected center frequency.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:DPHAse


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:DPHAse?
Query Response:
        <MeandPhase>
      

Description

Fetches the I/Q versus time (IQVT) delta phase result.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeandPhase>

Description

Mean delta phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:FERRor


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:FERRor?
Query Response:
        <MeanFrequencyError>
      

Description

Fetches the I/Q versus time (IQVT) frequency error result.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanFrequencyError>

Description

Mean frequency error evaluated over the specified interval and compared to the expected center frequency.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:PHASe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:PHASe?
Query Response:
        <MeanPhase>
      

Description

Fetches the I/Q versus time (IQVT) phase result.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPhase>

Description

Mean phase evaluated over the specified interval.

Datatype

Double

Unit

Deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:POWer


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:IQVTime:POWer?
Query Response:
        <MeanPower>
      

Description

Fetches the I/Q versus time (IQVT) power result.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPower>

Description

Mean power evaluated over the specified interval.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:FCOunt:FREQuency[:AVERage]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:FCOunt:FREQuency[:AVERage]?
Query Response:
        <MeanFrequencyError[n]>
      

Description

Fetches the frequency counter frequency error results for a given segment.

Availability

Query

Execution Mode

Sequential

Parameter: <MeanFrequencyError[n]>

Description

Average frequency error for each slot in the segment. The frequency error is the mean frequency delta to the requested freqency value  evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:FCOunt:PHASe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:FCOunt:PHASe?
Query Response:
        <MeanPhase[n]>
      

Description

Fetches the frequency counter phase results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPhase[n]>

Description

Phase for each slot in the segment. The phase is the mean phase evaluated over the specified interval.

Datatype

Double

Unit

deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:DPHAse


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:DPHAse?
Query Response:
        <MeanDeltaPhase[n]>
      

Description

Fetches the I/Q versus time (IQVT) delta phase results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanDeltaPhase[n]>

Description

Delta phase for each slot in the segment.

Datatype

Double

Unit

deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:FERRor


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:FERRor?
Query Response:
        <MeanFrequencyError[n]>
      

Description

Fetches the I/Q versus time (IQVT) frequency error results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanFrequencyError[n]>

Description

Frequency error for each slot in the segment. The frequency error is the mean frequency error evaluated over the specified interval and compared to the expected center frequency.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:OFERror


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:OFERror?
Query Response:
        <OverallMeanFrequencyError>
      

Description

Fetches the I/Q versus time (IQVT) overall frequency error results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <OverallMeanFrequencyError>

Description

Overall mean frequency error for the segment.

Datatype

Double

Unit

Hz

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:PHASe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:PHASe?
Query Response:
        <MeanPhase[n]>
      

Description

Fetches the I/Q versus time (IQVT) delta phase results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MeanPhase[n]>

Description

Phase for each slot in the segment.

Datatype

Double

Unit

deg

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:POWer


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:IQVTime:POWer?
Query Response:
        <AveragePower[n]>
      

Description

Fetches the I/Q versus time (IQVT) delta phase results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <AveragePower[n]>

Description

Average power for each slot in the segment.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower[:AVERage]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower[:AVERage]?
Query Response:
        <AveragePower[n]>
      

Description

Fetches the transmit power (TXP) power results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <AveragePower[n]>

Description

Average power for each slot in the segment. The power is the mean power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:MAXimum


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:MAXimum?
Query Response:
        <MaximumPower[n]>
      

Description

Fetches the transmit power (TXP) power results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MaximumPower[n]>

Description

Maximum power for each slot in the segment. The power is the maximum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:MINimum


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:MINimum?
Query Response:
        <MinimumPower[n]>
      

Description

Fetches the transmit power (TXP) power results for a given segment.

Availability

Query

Execution Mode

Overlapped

Parameter: <MinimumPower[n]>

Description

Minimum power for each slot in the segment. The power is the minimum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:TRACe[:POWer]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:SEQuence:SEGMent<i>:TXPower:TRACe[:POWer]?
Query Response:
        <Xo>,<dx>,#xyy<TxpPowerTrace[n]>
      

Description

Fetches the transmit power (TXP) power results for a given segment. This value is available only when traces are enabled.

Availability

Query

Execution Mode

Overlapped

Parameter: <Xo>

Description

Origin point of the x-axis of trace data (start time).

Datatype

Double

Parameter: <dx>

Description

Delta time between each sample in the trace.

Datatype

Double

Parameter: #xyy<TxpPowerTrace[n]>

Description

Trace data values.

Datatype

Real Blockdata (8 Byte Doubles)

FETCh:RFSA:GPRF<i>[:RESults<i>]:STATe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:STATe?
Query Response:
        <HardwareState>,<MeasurementState>
      

Description

Returns the state of the instrument.

Availability

Query

Execution Mode

Overlapped

Parameter: <HardwareState>

Description

IDLE: Hardware is available.
            PENDING: Execution is waiting for hardware to release.
            ACTIVE: Hardware is actively acquiring data.

Datatype

Enumeration

Parameter: <MeasurementState>

Description

OFF: The measurement has not been initiated yet.
            READY: The measurement result is available to fetch.
            PENDING: The measurement is initiated but has not started receiving data to process.
            PROCESSING: The measurement is processing the acquired data.

Datatype

Enumeration

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower[:ALL]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower[:ALL]?
Query Response:
        <AverageMeanPower>,<PeakToAverageRatio>,<MaxPower>,<MinPower>
      

Description

Fetches the transmission power (TXP) power results.

Availability

Query

Execution Mode

Overlapped

Parameter: <AverageMeanPower>

Description

Average power is the mean power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

Parameter: <PeakToAverageRatio>

Description

Peak to average TXP ratio.

Datatype

Double

Unit

dB

Parameter: <MaxPower>

Description

Maximum power is the maximum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

Parameter: <MinPower>

Description

Minimum power is the minimum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:AVERage


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:AVERage?
Query Response:
        <AverageMeanPower>
      

Description

Fetches the transmit power (TXP) power results.

Availability

Query

Execution Mode

Overlapped

Parameter: <AverageMeanPower>

Description

Average power is the mean power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:MAXimum


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:MAXimum?
Query Response:
        <MaxPower>
      

Description

Fetches the transmit power (TXP) power results.

Availability

Query

Execution Mode

Overlapped

Parameter: <MaxPower>

Description

Maximum power is the maximum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:MINimum


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:MINimum?
Query Response:
        <MinPower>
      

Description

Fetches the transmit power (TXP) power results.

Availability

Query

Execution Mode

Overlapped

Parameter: <MinPower>

Description

Minimum power is the minimum power evaluated over the specified interval.
            The averaging is controlled by the configured type and number of averages.

Datatype

Double

Unit

dBm

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:PTARatio


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:PTARatio?
Query Response:
        <PeakToAverageRatio>
      

Description

Fetches the transmit power (TXP) power results.

Availability

Query

Execution Mode

Overlapped

Parameter: <PeakToAverageRatio>

Description

Peak to average TXP ratio.

Datatype

Double

Unit

dB

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe[:POWer]


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe[:POWer]?
Query Response:
        <Xo>,<dx>,#xyy<TxpPowerTrace[n]>
      

Description

Fetches the transmission power (TXP) power trace.

Availability

Query

Execution Mode

Overlapped

Parameter: <Xo>

Description

Origin point of the x-axis of trace data (start time).

Datatype

Double

Parameter: <dx>

Description

Delta time between each sample in the trace.

Datatype

Double

Parameter: #xyy<TxpPowerTrace[n]>

Description

Trace data values, sent as binary block data.

Datatype

Real Blockdata (8 Byte Doubles)

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe:IQ


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe:IQ?
Query Response:
        <Xo>,<dx>,#xyy<TxpIQTrace[n]>
      

Description

Fetches the I/Q samples from the measurement. The array consists of interleaved I and Q samples. The size of the array is the total size (twice the size of the I/Q samples as they are interleaved).

Availability

Query

Execution Mode

Overlapped

Parameter: <Xo>

Description

Origin point of the x-axis of trace data (start time).

Datatype

Double

Parameter: <dx>

Description

Delta time between each sample in the trace.

Datatype

Double

Parameter: #xyy<TxpIQTrace[n]>

Description

Trace data values, sent as binary complex block data.

Datatype

Complex Blockdata (8 Byte Doubles)

FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe:PHASe


        Usage:
        FETCh:RFSA:GPRF<i>[:RESults<i>]:TXPower:TRACe:PHASe?
Query Response:
        <Xo>,<dx>,#xyy<TxpPhaseTrace[n]>
      

Description

Fetches the transmit power (TXP) phase trace.

Availability

Query

Execution Mode

Overlapped

Parameter: <Xo>

Description

Origin point of the x-axis of trace data (start time).

Datatype

Double

Parameter: <dx>

Description

Delta time between each sample in the trace.

Datatype

Double

Parameter: #xyy<TxpPhaseTrace[n]>

Description

Trace data values, sent as binary block data.

Datatype

Real Blockdata (8 Byte Doubles)

INITiate:RFSA:GPRF<i>[:RESults<i>]


        Usage:
        INITiate:RFSA:GPRF<i>[:RESults<i>]
      

Description

Initiates a composite measurement and stores the results in the result space provided in [:Result<i>].

Availability

Command

Execution Mode

Sequential

INITiate:RFSA:GPRF<i>:ALEVel


        Usage:
        INITiate:RFSA:GPRF<i>:ALEVel
      

Description

This command blocks the instrument until the AutoLevel task completes.

Availability

Command

Execution Mode

Sequential

SYSTem:RFSA:GPRF<i>:VERSion


        Usage:
        SYSTem:RFSA:GPRF<i>:VERSion?
Query Response:
        <PersonalityVersion>,<FrameworkVersion>
      

Description

Availability

Query

Execution Mode

Overlapped

Parameter: <PersonalityVersion>

Description

Version of the SCPI personality.

Datatype

String

Parameter: <FrameworkVersion>

Description

Version of the execution framework.

Datatype

String

TRIGger:RFSA:GPRF<i>:DELay


        Usage:
        TRIGger:RFSA:GPRF<i>:DELay[?] <TriggerDelay>
Query Response:
        <TriggerDelay>
      

Description

Specifies the trigger delay, which is the delay between the trigger point and the start of data acquisition.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TriggerDelay>

Description

Trigger delay.

Datatype

Double

Default Value

0.00E+000

Range

[-1.00E+001:1.00E+001]

Unit

S

TRIGger:RFSA:GPRF<i>:EDGE


        Usage:
        TRIGger:RFSA:GPRF<i>:EDGE[?] <TriggerEdge>
Query Response:
        <TriggerEdge>
      

Description

Specifies whether the trigger asserts on the rising or falling edge of the signal.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TriggerEdge>

Description

RISing: Asserts the trigger on the rising edge of the signal.
            FALLing: Asserts the trigger on the falling edge of the signal.

Datatype

Enumeration

Default Value

RISing

Range

RISing | FALLing

TRIGger:RFSA:GPRF<i>:EXPort


        Usage:
        TRIGger:RFSA:GPRF<i>:EXPort[?] <TriggerExportDestination>
Query Response:
        <TriggerExportDestination>
      

Description

Specifies whether to export the trigger to allow other configurations to capture the event and react to the trigger as well.

Availability

Command/Query

Execution Mode

Command: Sequential
Query: Sequential

Parameter: <TriggerExportDestination>

Description

NONE: The trigger is not exported.
            INTERNAL: The trigger is exported internally in the instrument.

Datatype

Enumeration

Default Value

NONE

Range

NONE | INTERNAL

TRIGger:RFSA:GPRF<i>:MQTime


        Usage:
        TRIGger:RFSA:GPRF<i>:MQTime[?] <MinQuietTimeDuration>
Query Response:
        <MinQuietTimeDuration>
      

Description

Specifies the minimum time for which the signal must be quiet before the device arms the trigger.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <MinQuietTimeDuration>

Description

Minimum quiet time. The signal is quiet when it is below the trigger level when you set the EDGE property to RISING, or above the trigger level when you set the EDGE property to FALLING.

Datatype

Double

Default Value

5.00E-006

Range

[0.00E+000:1.00E+001]

Unit

sec

TRIGger:RFSA:GPRF<i>:SOURce


        Usage:
        TRIGger:RFSA:GPRF<i>:SOURce[?] <TriggerSource>
Query Response:
        <TriggerSource>
      

Description

Specifies the source terminal for the trigger.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TriggerSource>

Description

IMMEDIATE - Generates the signal to measure when the hardware is ready.
            POWER - Uses RF power edge trigger.
            INTERNAL - Uses one of the multiple WTS internal triggers, which must be exported by any other personality configured to use the same port. The port name must be defined before this command is executed.

Datatype

String

Default Value

"IMMEDIATE"

TRIGger:RFSA:GPRF<i>:THReshold


        Usage:
        TRIGger:RFSA:GPRF<i>:THReshold[?] <TriggerThreshold>
Query Response:
        <TriggerThreshold>
      

Description

Specifies the trigger threshold to use when power triggering. This value is referenced to the unit under test (UUT) port, accounting for external attenuation.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TriggerThreshold>

Description

Power threshold relative to the currently set maximum expected power.

Datatype

Double

Default Value

-30.00

Range

[-100.00:0.00]

Unit

dB

TRIGger:RFSA:GPRF<i>:TOUT


        Usage:
        TRIGger:RFSA:GPRF<i>:TOUT[?] <TriggerTimeout>
Query Response:
        <TriggerTimeout>
      

Description

Specifies the maximum time allowed to meet the trigger condition after committing the configuration to the hardware.

Availability

Command/Query

Execution Mode

Command: Overlapped
Query: Overlapped

Parameter: <TriggerTimeout>

Description

Trigger timeout. The timeout watchdog does not start while the hardware configuration is pending.

Datatype

Double

Default Value

10.00

Range

[0.00:10000.00]

Unit

sec