Bluetooth RFSA SCPI Command Reference
- Updated2023-04-26
- 14 minute(s) read
Bluetooth RFSA SCPI Command Reference
SCPI command reference for the Bluetooth signal analyzer instrument personality.
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions[:ENABle][?] <IBEEnable>
Query Response:
<IBEEnable>
|
Description |
Specifies whether to enable InBandEmission measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <IBEEnable> | |
|
Description |
0 | OFF: Disables InBandEmission measurements. |
|
Datatype |
Boolean |
|
Default Value |
0 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:AVERage[:COUNt]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:AVERage[:COUNt][?] <IbeAverageCount>
Query Response:
<IbeAverageCount>
|
Description |
Specifies the number of acquisitions over which the WTS averages InBandEmission measurements using peak-hold averaging. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <IbeAverageCount> | |
|
Description |
Number of acquisitions over which the WTS averages InBandEmission measurements using peak-hold averaging. |
|
Datatype |
Integer32 |
|
Default Value |
1 |
|
Range |
[1:10000] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:CHANnel:COUNt
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:CHANnel:COUNt[?] <NumberOfChannels>
Query Response:
<NumberOfChannels>
|
Description |
Specifies the number of channels used for InBandEmission measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <NumberOfChannels> | |
|
Description |
Number of channels used for InBandEmission measurements. |
|
Datatype |
Integer32 |
|
Default Value |
7 |
|
Range |
[1:79] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:INTerval[:LENGth]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:INTerval[:LENGth][?] <IbemeasurementInterval>
Query Response:
<IbemeasurementInterval>
|
Description |
Specifies the measurement length over each burst for which InBandEmission is computed. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <IbemeasurementInterval> | |
|
Description |
IBE measurement interval. |
|
Datatype |
Double |
|
Default Value |
5.000000E-003 |
|
Range |
[1.000000E-006:1.000000E-001] |
|
Unit |
s |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:INTerval[:LENGth]:AUTO[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:IBEMissions:INTerval[:LENGth]:AUTO[:ENABle][?] <IBEAutoLengthEnable>
Query Response:
<IBEAutoLengthEnable>
|
Description |
Specifies whether to use automatic interval mode for InBandEmission measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <IBEAutoLengthEnable> | |
|
Description |
0 | OFF: Disables automatic interval mode. |
|
Datatype |
Boolean |
|
Default Value |
1 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation[:ENABle][?] <DemodualtionEnable>
Query Response:
<DemodualtionEnable>
|
Description |
Specifies whether to enable modulation accuracy (ModAcc) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <DemodualtionEnable> | |
|
Description |
0 | OFF: Disables ModAcc measurements. |
|
Datatype |
Boolean |
|
Default Value |
0 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:AVERage[:COUNt]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:AVERage[:COUNt][?] <ModulationAverageCount>
Query Response:
<ModulationAverageCount>
|
Description |
Specifies the number of acquisitions over which to average modulation measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ModulationAverageCount> | |
|
Description |
Number of acquisitions over which to average modulation measurements. |
|
Datatype |
Integer32 |
|
Default Value |
1 |
|
Range |
[1:10000] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:AVERage:TYPE
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:AVERage:TYPE[?] <ModulationAverageType>
Query Response:
<ModulationAverageType>
|
Description |
Specifies the averaging type for specified measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ModulationAverageType> | |
|
Description |
RMS - The power is averaged using root mean square. |
|
Datatype |
Enumeration |
|
Default Value |
RMS |
|
Range |
RMS | MAX | MIN |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CFO[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CFO[:ENABle][?] <CFOEnable>
Query Response:
<CFOEnable>
|
Description |
Specifies whether to enable carrier frequency offset (CFO) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <CFOEnable> | |
|
Description |
0 | OFF: Disables CFO measurements. |
|
Datatype |
Boolean |
|
Default Value |
0 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CHARacter[:SELect]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CHARacter[:SELect][?] <ModulationCharacteristicSelction>
Query Response:
<ModulationCharacteristicSelction>
|
Description |
Specifies whether to enable DF1 or DF2 measurements for BDR and LE-TP packets. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ModulationCharacteristicSelction> | |
|
Description |
Selects between the DF1 or DF2 measurement. |
|
Datatype |
Enumeration |
|
Default Value |
DF1 |
|
Range |
DF1 | DF2 |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CHARacter:RESet
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:FSK:CHARacter:RESet
|
Description |
Clears the memory of any DF1 or DF2 previously computed to help return the correct DF2/DF1 ratio. |
|
Availability |
Command |
|
Execution Mode |
Sequential |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:INTerval
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:INTerval[?] <ModAccMeasurementInterval>
Query Response:
<ModAccMeasurementInterval>
|
Description |
Specifies the measurement interval, in symbols, used for modulation measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ModAccMeasurementInterval> | |
|
Description |
Measurement interval in symbols. -1 uses the maximum value for the selected packet type. This value is used for DF1, DF2, and DEVM measurements. |
|
Datatype |
Integer32 |
|
Default Value |
-1 |
|
Range |
[-1:1024] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:OFFSet
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:MODulation:OFFSet[?] <ModAccMeasurementOffset>
Query Response:
<ModAccMeasurementOffset>
|
Description |
Specifies the measurement offset, in symbols, from the start of the packet to where the measurement interval begins. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ModAccMeasurementOffset> | |
|
Description |
Measurement offset in symbols. |
|
Datatype |
Integer32 |
|
Default Value |
0 |
|
Range |
[0:1023] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW[:ENABle][?] <ObwEnable>
Query Response:
<ObwEnable>
|
Description |
Specifies whether to enable occupied bandwidth (OBW) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ObwEnable> | |
|
Description |
0 | OFF: Disables OBW measurements. |
|
Datatype |
Boolean |
|
Default Value |
0 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:AVERage[:COUNt]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:AVERage[:COUNt][?] <ObwAverageCount>
Query Response:
<ObwAverageCount>
|
Description |
Specifies the number of acquisitions over which to average occupied bandwidth (OBW) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ObwAverageCount> | |
|
Description |
Number of acquisitions over which to average OBW measurements. |
|
Datatype |
Integer32 |
|
Default Value |
1 |
|
Range |
[1:10000] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:INTerval[:LENGth]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:INTerval[:LENGth][?] <ObwMeasurementInterval>
Query Response:
<ObwMeasurementInterval>
|
Description |
Specifies the measurement interval for the occupied bandwidth (OBW) measurement. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <ObwMeasurementInterval> | |
|
Description |
Measurement interval. |
|
Datatype |
Double |
|
Default Value |
5.000000E-003 |
|
Range |
[1.000000E-006:1.000000E-001] |
|
Unit |
s |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:INTerval[:LENGth]:AUTO[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:OBW:INTerval[:LENGth]:AUTO[:ENABle][?] <ObwEnableAutoLength>
Query Response:
<ObwEnableAutoLength>
|
Description |
Specifies whether to use automatic interval mode for occupied bandwidth (OBW) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <ObwEnableAutoLength> | |
|
Description |
0 | OFF: Disables automatic interval mode. |
|
Datatype |
Boolean |
|
Default Value |
1 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower[:ENABle][?] <TxPowerEnable>
Query Response:
<TxPowerEnable>
|
Description |
Specifies whether to enable transmit power (TXP) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TxPowerEnable> | |
|
Description |
0 | OFF: Disables TXP measurements. |
|
Datatype |
Boolean |
|
Default Value |
1 |
|
Range |
0 | 1 | OFF | ON |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower:AVERage[:COUNt]
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower:AVERage[:COUNt][?] <TxpAverageCount>
Query Response:
<TxpAverageCount>
|
Description |
Specifies the number of acquisitions over which to average transmit power (TXP) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TxpAverageCount> | |
|
Description |
Number of acquisitions over which to average TXP measurements. |
|
Datatype |
Integer32 |
|
Default Value |
1 |
|
Range |
[1:10000] |
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower:AVERage:TYPE
Usage:
CONFigure:RFSA:BLUetooth<i>[:MEASurement]:TXPower:AVERage:TYPE[?] <TxpAverageType>
Query Response:
<TxpAverageType>
|
Description |
Specifies the averaging type for the transmit power (TXP) measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TxpAverageType> | |
|
Description |
RMS - The power is averaged using root mean square. |
|
Datatype |
Enumeration |
|
Default Value |
RMS |
|
Range |
RMS | LOG | SCALar | MAX | MIN |
CONFigure:RFSA:BLUetooth<i>:BDADdress
Usage:
CONFigure:RFSA:BLUetooth<i>:BDADdress[?] <BDADdress>
Query Response:
<BDADdress>
|
Description |
Specifies the Bluetooth device address. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <BDADdress> | |
|
Description |
BDADdress consists of 3-parts: |
|
Datatype |
Integer64 |
|
Default Value |
#H0 |
|
Range |
[#H0:#H7FFFFFFFFFFF] |
CONFigure:RFSA:BLUetooth<i>:BSYNc
Usage:
CONFigure:RFSA:BLUetooth<i>:BSYNc[?] <BurstSyncType>
Query Response:
<BurstSyncType>
|
Description |
Specifies the type of synchronization used for detecting the start of the packet. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <BurstSyncType> | |
|
Description |
PREamble: The instrument uses the packet preamble to synchronize the packet. |
|
Datatype |
Enumeration |
|
Default Value |
PREamble |
|
Range |
PREamble | NONE |
CONFigure:RFSA:BLUetooth<i>:EATTenuation
Usage:
CONFigure:RFSA:BLUetooth<i>:EATTenuation[?] <ExternalAttenuation>
Query Response:
<ExternalAttenuation>
|
Description |
Specifies the external attenuation. External attenuation is applied on top of any attenuation provided for the specified port. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <ExternalAttenuation> | |
|
Description |
External attenuation. |
|
Datatype |
Double |
|
Default Value |
0.00 |
|
Range |
[-100.00:100.00] |
|
Unit |
dB |
CONFigure:RFSA:BLUetooth<i>:FREQuency[:CENTer]
Usage:
CONFigure:RFSA:BLUetooth<i>:FREQuency[:CENTer][?] <Frequency>
Query Response:
<Frequency>
|
Description |
Specifies the center frequency. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <Frequency> | |
|
Description |
Center frequency. |
|
Datatype |
Double |
|
Default Value |
2.402000000000000E+009 |
|
Range |
[6.500000000000000E+007:6.000000000000000E+009] |
|
Unit |
Hz |
CONFigure:RFSA:BLUetooth<i>:FREQuency:CHANnel
Usage:
CONFigure:RFSA:BLUetooth<i>:FREQuency:CHANnel <Channel>
|
Description |
Specifies the frequency channel. |
|
Availability |
Command |
|
Execution Mode |
Overlapped |
| Parameter: <Channel> | |
|
Description |
Computes the center frequency of the Bluetooth signal transmitted by the WTS based on the value that you specify in the channel number parameter. The center frequency is computed according to section 2, Volume 2 of the Bluetooth Specification v2.1+EDR. |
|
Datatype |
Integer32 |
|
Default Value |
0 |
|
Range |
[0:78] |
CONFigure:RFSA:BLUetooth<i>:PACKet
Usage:
CONFigure:RFSA:BLUetooth<i>:PACKet[?] <PacketType>,<PacketPayloadDatarate>
Query Response:
<PacketType>,<PacketPayloadDatarate>
|
Description |
Specifies the packet type of the signal to be measured. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <PacketType> | |
|
Description |
DH1: Uses the DH1 packet type. |
|
Datatype |
Enumeration |
|
Default Value |
DH1 |
|
Range |
DH1 | DH3 | DH5 | LETP | LETP_EXT | LE_ENHANCED | LE_LR125K | LE_LR500K |
| Parameter: <PacketPayloadDatarate> | |
|
Description |
Packet payload data rate, in MHz. |
|
Datatype |
Integer32 |
|
Default Value |
1 |
|
Range |
[1:3] |
CONFigure:RFSA:BLUetooth<i>:PORTname
Usage:
CONFigure:RFSA:BLUetooth<i>:PORTname[?] <PortName>
Query Response:
<PortName>
|
Description |
Specifies the port name. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <PortName> | |
|
Default Value |
"Port0" |
CONFigure:RFSA:BLUetooth<i>:POWer[:MAXimum]
Usage:
CONFigure:RFSA:BLUetooth<i>:POWer[:MAXimum][?] <MaxInputPower>
Query Response:
<MaxInputPower>
|
Description |
Specifies the maximum expected input power to the instrument. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <MaxInputPower> | |
|
Default Value |
0.00 |
|
Range |
[-174.00:50.00] |
|
Unit |
dBm |
CONFigure:RFSA:BLUetooth<i>:TRACe[:ENABle]
Usage:
CONFigure:RFSA:BLUetooth<i>:TRACe[:ENABle][?] <TracesEnable>
Query Response:
<TracesEnable>
|
Description |
Specifies whether to enable collection of trace data for general purpose RF measurements. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TracesEnable> | |
|
Description |
If disabled, no trace data is collected so no traces can be fetched. |
|
Datatype |
Boolean |
|
Default Value |
0 |
|
Range |
0 | 1 | OFF | ON |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:IBEMissions[:AVERage]
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:IBEMissions[:AVERage]?
Query Response:
<MeasurementStatus>,<ReferenceChannelPower>,<UpperChannelTotalPower>,<LowerChannelTotalPower>,<TotalChannelPower[n]>
|
Description |
Fetches the status for the InBandEmission measurement based on the measurement limits specified in section 5.1.15 of the Bluetooth Test Specification v1.2/2.0/2.0+EDR/2.1/2.1+EDR/3.0/3.0+HS/4.0. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <MeasurementStatus> | |
|
Description |
FAIL: Measurement results do not satisfy the limits. |
|
Datatype |
Enumeration |
| Parameter: <ReferenceChannelPower> | |
|
Description |
Peak power of the center channel. |
|
Datatype |
Double |
|
Unit |
dBm |
| Parameter: <UpperChannelTotalPower> | |
|
Description |
Peak power of the upper channel adjacent to the center frequency. |
|
Datatype |
Double |
|
Unit |
dBm |
| Parameter: <LowerChannelTotalPower> | |
|
Description |
Peak power of the lower channel adjacent to the center frequency. |
|
Datatype |
Double |
|
Unit |
dBm |
| Parameter: <TotalChannelPower[n]> | |
|
Unit |
dBm |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:IBEMissions:TRACe
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:IBEMissions:TRACe?
Query Response:
<Xo>,<dx>,#xyy<InBAndEmissionsTrace[n]>
|
Description |
Fetches the InBandEmission trace. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <Xo> | |
|
Description |
Trace origin point (start frequency). |
|
Datatype |
Double |
| Parameter: <dx> | |
|
Description |
Trace delta value between points (delta frequency). |
|
Datatype |
Double |
| Parameter: #xyy<InBAndEmissionsTrace[n]> | |
|
Description |
Trace values sent as binary block data. |
|
Datatype |
Real Blockdata (8 Byte Doubles) |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:CFSTability
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:CFSTability?
Query Response:
<AverageInitialFrequencyError>,<MaxInitialFrequencyError>,<AverageBlockAbsFrequencyError>,<MaxBlockAbsFrequencyError>,<AverageBlockRelFrequencyError>,<MaxBlockRelFrequencyError>
|
Description |
Fetches carrier frequency measurement results. Results are valid for enhanced data rate (EDR) packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <AverageInitialFrequencyError> | |
|
Description |
Average initial carrier frequency tolerance (ICFT). |
|
Datatype |
Double |
|
Unit |
Hz |
| Parameter: <MaxInitialFrequencyError> | |
|
Description |
Maximum initial carrier frequency tolerance (ICFT). |
|
Datatype |
Double |
|
Unit |
Hz |
| Parameter: <AverageBlockAbsFrequencyError> | |
|
Unit |
Hz |
| Parameter: <MaxBlockAbsFrequencyError> | |
|
Unit |
Hz |
| Parameter: <AverageBlockRelFrequencyError> | |
|
Unit |
Hz |
| Parameter: <MaxBlockRelFrequencyError> | |
|
Unit |
Hz |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM?
Query Response:
<AverageRmsDevm>,<MaxPeakDevm>,<99pctDevm>
|
Description |
Fetches differential error vector magnitude (DEVM) results. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <AverageRmsDevm> | |
|
Description |
Average of RMS DEVM measurements. |
|
Datatype |
Double |
|
Unit |
% |
| Parameter: <MaxPeakDevm> | |
|
Description |
Maximum of peak EVM measurements. |
|
Datatype |
Double |
|
Unit |
% |
| Parameter: <99pctDevm> | |
|
Description |
99 percent DEVM. |
|
Datatype |
Double |
|
Unit |
% |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM:TRACe[:BLOCk]
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM:TRACe[:BLOCk]?
Query Response:
<Xo>,<dx>,#xyy<DevmTraceData[n]>
|
Description |
Fetches the differential error vector magnitude (DEVM) trace. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <Xo> | |
|
Description |
Trace origin point (start time). |
|
Datatype |
Double |
| Parameter: <dx> | |
|
Description |
Trace delta value between points (delta time). |
|
Datatype |
Double |
| Parameter: #xyy<DevmTraceData[n]> | |
|
Description |
Trace values sent as binary block data. |
|
Datatype |
Real Blockdata (8 Byte Doubles) |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM:TSYMbols
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:DEVM:TSYMbols?
Query Response:
<SymbolsUnder99pctDEVM>
|
Description |
Returns the number of symbols below the 99% DEVM. This is helpful to know by how many symbols are (or are not) measured by the standard defined 99% DEVM (defined as the DEVM value for which 99% of measured symbols |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <SymbolsUnder99pctDEVM> | |
|
Unit |
symbols |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:IMPairments
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:EDR:IMPairments?
Query Response:
<AverageIqImbalance>,<AvgQuadratureSkew>,<AvgIOffset>,<AvgQOffset>
|
Description |
Fetches impairments measurement results. Results are valid for enhanced data rate (EDR) packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <AverageIqImbalance> | |
|
Description |
The result across iterations of I/Q gain imbalance estimates. I/Q gain imbalance is the ratio of the mean amplitude of the in-phase (I) signal to the mean amplitude of the quadrature-phase (Q) signal. |
|
Datatype |
Double |
|
Unit |
dB |
| Parameter: <AvgQuadratureSkew> | |
|
Description |
The result across iterations of quadrature skew estimates. Quadrature skew is the deviation in angle from 90 degrees between the in-phase (I) and quadrature-phase (Q) signals. |
|
Datatype |
Double |
|
Unit |
deg |
| Parameter: <AvgIOffset> | |
|
Description |
The result across iterations of the in-phase (I) offset. |
|
Datatype |
Double |
|
Unit |
% |
| Parameter: <AvgQOffset> | |
|
Description |
The result across iterations of the quadrature-phase (Q) offset. |
|
Datatype |
Double |
|
Unit |
% |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:CFO
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:CFO?
Query Response:
<IcftMax>,<MaxCarrierDrift>,<MaxCarrierDrift/50us>,<MaxPayloadBlockFreqOffset>,<MaxCarrierDrift/55us>
|
Description |
Fetches carrier frequency offset results. ICFTMax , MaxCarrierDrift and MaxCarrierDrift/50us results are valid for basic data rate (BDR) packets and LE-TP packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <IcftMax> | |
|
Unit |
Hz |
| Parameter: <MaxCarrierDrift> | |
|
Unit |
Hz |
| Parameter: <MaxCarrierDrift/50us> | |
|
Unit |
Hz |
| Parameter: <MaxPayloadBlockFreqOffset> | |
|
Unit |
Hz |
| Parameter: <MaxCarrierDrift/55us> | |
|
Unit |
Hz |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:CHARacter
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:CHARacter?
Query Response:
<MeasurementStatusDf1>,<AverageDf1Avg>,<MaxDf1Max>,<MinDf1Max>,<MeasurementStatusDf2>,<AverageDf2Avg>,<MaxDf2Max>,<MinDf2Max>,<AverageDf2avg/AverageDf1avg>
|
Description |
Fetches DF1 and DF2 measurement results. Results are valid for basic data rate (BDR) packets and LE-TP packets. Note: You must first perform both DF1 and DF2 measurements to receive valid values for the DF2/DF1 result. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <MeasurementStatusDf1> |
| Parameter: <AverageDf1Avg> | |
|
Unit |
Hz |
| Parameter: <MaxDf1Max> | |
|
Unit |
Hz |
| Parameter: <MinDf1Max> | |
|
Unit |
Hz |
| Parameter: <MeasurementStatusDf2> |
| Parameter: <AverageDf2Avg> | |
|
Unit |
Hz |
| Parameter: <MaxDf2Max> | |
|
Unit |
Hz |
| Parameter: <MinDf2Max> | |
|
Unit |
Hz |
| Parameter: <AverageDf2avg/AverageDf1avg> |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:TRACe:CFO
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:TRACe:CFO?
Query Response:
<Xo>,<dx>,#xyy<CfoTraceData[n]>
|
Description |
Fetches carrier frequency offset traces. Traces are valid for basic data rate (BDR) packets and LE-TP packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <Xo> |
| Parameter: <dx> |
| Parameter: #xyy<CfoTraceData[n]> |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:TRACe:CHARacter
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:MODulation:FSK:TRACe:CHARacter?
Query Response:
<XoDf>,<dxDf>,#xyy<DfTraceData[n]>
|
Description |
Fetches DF trace. The trace represents the frequency deviation versus symbol. These traces help ensure that the pattern is that needed for DF1 or DF2. Traces are valid for basic data rate (BDR) packets and LE-TP packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <XoDf> |
| Parameter: <dxDf> |
| Parameter: #xyy<DfTraceData[n]> |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:OBW[:AVERage]
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:OBW[:AVERage]?
Query Response:
<OccupiedBandwidth>,<StartFrequency>,<StopFrequency>
|
Description |
Fetches occupied bandwidth (OBW) results. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <OccupiedBandwidth> | |
|
Description |
Average OBW of the signal. |
|
Datatype |
Double |
|
Unit |
Hz |
| Parameter: <StartFrequency> | |
|
Description |
Average of the lower-bound frequency of the OBW measurements. |
|
Datatype |
Double |
|
Unit |
Hz |
| Parameter: <StopFrequency> | |
|
Description |
Average of the upper-bound frequency of the OBW measurements. |
|
Datatype |
Double |
|
Unit |
Hz |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:OBW:TRACe
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:OBW:TRACe?
Query Response:
<Xo>,<dx>,#xyy<ObwTraceData[n]>
|
Description |
Fetches occupied bandwidth (OBW) traces. Traces are valid only for basic data rate (BDR) packets. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <Xo> |
| Parameter: <dx> |
| Parameter: #xyy<ObwTraceData[n]> |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:STATe
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:STATe?
Query Response:
<HardwareState>,<MeasurementState>
|
Description |
Fetches the state of the instrument. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <HardwareState> | |
|
Description |
IDLE: Hardware is available. |
|
Datatype |
Enumeration |
| Parameter: <MeasurementState> | |
|
Description |
OFF: The measurement has not been initiated yet. |
|
Datatype |
Enumeration |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:TXPower[:AVERage]
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:TXPower[:AVERage]?
Query Response:
<AverageBurstPower>,<AveragePeakBurstPower>,<EdrRelativePower>
|
Description |
Fetches transmit power (TXP) results. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <AverageBurstPower> | |
|
Description |
Average of the average mean power results. |
|
Datatype |
Double |
| Parameter: <AveragePeakBurstPower> | |
|
Description |
Average of the peak burst power. |
|
Datatype |
Double |
| Parameter: <EdrRelativePower> | |
|
Description |
Relative power difference between the payload and the header power. |
|
Datatype |
Double |
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:TXPower:TRACe[:POWer]
Usage:
FETCh:RFSA:BLUetooth<i>[:RESults<i>]:TXPower:TRACe[:POWer]?
Query Response:
<Xo>,<dx>,#xyy<TxpTraceData[n]>
|
Description |
Fetches the transmit power (TXP) trace. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <Xo> | |
|
Description |
Trace origin point (start time). |
|
Datatype |
Double |
| Parameter: <dx> | |
|
Description |
Trace delta value between points (delta time). |
|
Datatype |
Double |
| Parameter: #xyy<TxpTraceData[n]> | |
|
Description |
Trace values sent as binary block data. |
|
Datatype |
Real Blockdata (8 Byte Doubles) |
INITiate:RFSA:BLUetooth<i>[:RESults<i>]
Usage:
INITiate:RFSA:BLUetooth<i>[:RESults<i>]
|
Description |
Initiates a composite Bluetooth measurement and stores the results in the results space provided in [:Result<i>]. |
|
Availability |
Command |
|
Execution Mode |
Sequential |
INITiate:RFSA:BLUetooth<i>:ALEVel
Usage:
INITiate:RFSA:BLUetooth<i>:ALEVel
|
Description |
This command blocks the instrument until the AutoLevel task completes. |
|
Availability |
Command |
|
Execution Mode |
Sequential |
SYSTem:RFSA:BLUetooth<i>:VERSion
Usage:
SYSTem:RFSA:BLUetooth<i>:VERSion?
Query Response:
<PersonalityVersion>,<FrameworkVersion>
|
Description |
Queries for the version of the RF General Settings personality. |
|
Availability |
Query |
|
Execution Mode |
Sequential |
| Parameter: <PersonalityVersion> | |
|
Description |
Version of the SCPI personality. |
|
Datatype |
String |
| Parameter: <FrameworkVersion> | |
|
Description |
Version of the execution framework. |
|
Datatype |
String |
TRIGger:RFSA:BLUetooth<i>:DELay[:TIME]
Usage:
TRIGger:RFSA:BLUetooth<i>:DELay[:TIME][?] <TriggerDelay>
Query Response:
<TriggerDelay>
|
Description |
Specifies the delay between the trigger and the start of data acquisition. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TriggerDelay> | |
|
Default Value |
0.000000000000000E+000 |
|
Range |
[-1.000000000000000E+001:1.000000000000000E+001] |
|
Unit |
Sec |
TRIGger:RFSA:BLUetooth<i>:DELay:PACKet
Usage:
TRIGger:RFSA:BLUetooth<i>:DELay:PACKet[?] <PacketDelay>
Query Response:
<PacketDelay>
|
Description |
Change this to delay the measurement by an integer number of packets. Each packet is detected by the trigger time selected until this count is reached. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <PacketDelay> | |
|
Description |
Number of packets to ignore before the measurement. |
|
Datatype |
Integer32 |
|
Default Value |
0 |
|
Range |
[0:1000] |
TRIGger:RFSA:BLUetooth<i>:EDGE
Usage:
TRIGger:RFSA:BLUetooth<i>:EDGE[?] <TriggerEdge>
Query Response:
<TriggerEdge>
|
Description |
Specifies whether the trigger asserts on the rising or falling edge of the signal. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TriggerEdge> | |
|
Description |
RISING: Asserts the trigger on the rising edge of the signal. |
|
Datatype |
Enumeration |
|
Default Value |
RISing |
|
Range |
RISing | FALLing |
TRIGger:RFSA:BLUetooth<i>:MQTime
Usage:
TRIGger:RFSA:BLUetooth<i>:MQTime[?] <MinQuietTimeDuration>
Query Response:
<MinQuietTimeDuration>
|
Description |
Specifies the minimum time for which the signal must be quiet before the device arms the trigger. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <MinQuietTimeDuration> | |
|
Description |
Minimum quiet time. The signal is quiet when it is below the trigger level when you set the EDGE property to RISING, or above the trigger level when you set the EDGE property to FALLING. |
|
Datatype |
Double |
|
Default Value |
1.000000000000000E-004 |
|
Range |
[0.000000000000000E+000:5.000000000000000E-003] |
|
Unit |
sec |
TRIGger:RFSA:BLUetooth<i>:SOURce
Usage:
TRIGger:RFSA:BLUetooth<i>:SOURce[?] <TriggerSource>
Query Response:
<TriggerSource>
|
Description |
Specifies the trigger source. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Sequential |
| Parameter: <TriggerSource> | |
|
Description |
IMMEDIATE - Generates the signal to measure as soon as the hardware is ready. |
|
Datatype |
String |
|
Default Value |
"POWER" |
TRIGger:RFSA:BLUetooth<i>:THReshold
Usage:
TRIGger:RFSA:BLUetooth<i>:THReshold[?] <TriggerThreshold>
Query Response:
<TriggerThreshold>
|
Description |
Specifies the trigger threshold to use when power triggering. This value is referenced to the unit under test (UUT) port, accounting for external attenuation. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TriggerThreshold> | |
|
Description |
Power threshold that is relative to the maximum power. |
|
Datatype |
Double |
|
Default Value |
-30.000 |
|
Range |
[-100.000:0.000] |
|
Unit |
dBm |
TRIGger:RFSA:BLUetooth<i>:TOUT
Usage:
TRIGger:RFSA:BLUetooth<i>:TOUT[?] <TriggerTimeout>
Query Response:
<TriggerTimeout>
|
Description |
Specifies the trigger timeout. |
|
Availability |
Command/Query |
|
Execution Mode |
Command: Overlapped |
| Parameter: <TriggerTimeout> | |
|
Default Value |
5.000000000000000E+000 |
|
Range |
[0.000000000000000E+000:1.000000000000000E+002] |
|
Unit |
sec |