19419: LabVIEW Projects Consolidation Failed because of Conflict between Loose VIs and VIs Project References
- Updated2026-02-03
- 1 minute(s) read
19419: LabVIEW Projects Consolidation Failed because of Conflict between Loose VIs and VIs Project References
Message
Cannot consolidate LabVIEW projects because some VIs are referenced by test sequences in the context of a LabVIEW project and outside the context of a LabVIEW project.
Why does this information message occur?
The deployment includes sequence files that refer to VIs using a LabVIEW project and without using a LabVIEW project, and you have enabled the Consolidate Files Projects Share option in the LabVIEW VI Options dialog box. For example, you have one top-level VI in a step configured to call the VI in the context of a LabVIEW project and another VI called in a step configured to call the VI without using a LabVIEW project.
How do I resolve this information message?
Use the following suggestions to resolve the issue.
- Ensure all VIs in the deployment are called only in the context of a LabVIEW project (not necessarily the same project for all of them) or outside the context of a LabVIEW project but not both.
- Disable the Consolidate Files Projects Share option in the LabVIEW VI Options dialog box.
If the issue persists, contact National Instruments for support. Save a technical support record to send to National Instruments by selecting Save Technical Support Report from the Save Log button pull-down menu.