19409: LLB Missing Files in Patch Deployment
- Updated2026-02-03
- 1 minute(s) read
19409: LLB Missing Files in Patch Deployment
Message
The following LLBs do not contain all the VIs that were included in the dependency deployment:
Why does this information message occur?
The LLBs specified in the error message contained one or more files in the dependent deployment that are no longer included in the LLBs in the patch deployment. The deployment utility did not include these files because the sequence files in the current deployment no longer reference the files. Any VIs that dynamically call into these VIs will be broken.
How do I resolve this information message?
If you are calling these VIs dynamically, add them to the LLB to include them with the deployment. If the files were top-level files installed in an LLB destination, add the files to the TestStand workspace to include the files in the deployment and change the destination on the Distributed Files tab so the files install in the destination LLB.
If the issue persists, contact National Instruments for support. Save a technical support record to send to National Instruments by selecting Save Technical Support Report from the Save Log button pull-down menu.