19201: Version Not Updated In Patch (Warning)
- Updated2026-02-03
- 1 minute(s) read
19201: Version Not Updated In Patch (Warning)
Message
The file version of the following files included in the patch deployment is not greater than the file version of the file included in the full deployment:
Why does this warning occur?
One or more of the versioned files included in the patch deployment use the same version as the dependent installer. Installers created with the deployment utility use the file version to determine if files have to be installed in the test system. Not incrementing the file versions when modifying the files could lead to a broken system.
How do I resolve this warning?
In the active version of the LabVIEW development system, use the build specifications properties page to increment the file versions. In LabWindows/CVI use the Version Info option in the Target Settings dialog box to increment the file versions. In Visual Studio, use the Project Properties tab to increment the file versions.
If the issue persists, contact National Instruments for support. Save a technical support record to send to National Instruments by selecting Save Technical Support Report from the Save Log button pull-down menu.