Sequence.GetBreakOnEndSettings
- Updated2025-07-21
- 1 minute(s) read
Sequence.GetBreakOnEndSettings
Syntax
Sequence.GetBreakOnEndSettings( stepGroupParam, isSet, enabled, passCount, Condition, [executionParam])
Purpose
Returns a value that indicates whether the step group of the sequence is set to break when all the steps in the sequence execute.
Parameters
stepGroupParam As StepGroups
[In] Specifies a particular step group.
isSet As Boolean
[Out] Returns a value that indicates whether the breakpoint is set.
enabled As Boolean
[Out] Returns a value that indicates whether the breakpoint is enabled. TestStand ignores disabled breakpoints during execution.
passCount As Long
[Out] Returns the number of times the execution must evaluate the condition expression before suspending the execution. Pass 0 if you do not want to use a conditional pass count.
Condition As String
[Out] Returns the expression that must evaluate to True before suspending the execution. An empty value defaults to True . If you specify a non-zero value for the passCount parameter and a condition expression for the breakpoint, the pass count decrements only when the expression evaluates to True .
executionParam As Variant
[In] [ Optional ] Pass a reference to an Execution object to obtain the breakpoint settings on the End step, which apply to a particular execution. If there is no execution-specific breakpoint setting or if you do not pass an Execution object, the method returns the breakpoint setting on the End step of the sequence file.