Formatting Configuration Data: Routes
- Updated2023-02-21
- 2 minute(s) read
Use the following guidelines when formatting Routes in Excel.
![]() |
Note NI Switch Executive replaces the attribute value with "Imported Value if Unspecified" only at import. If "Imported Value if Unspecified" is N/A, NI Switch Executive ignores the attribute at import. |
Attribute (Column) | Valid Values | Required | Imported Value if Unspecified |
---|---|---|---|
Route Name | String | Yes | None |
Endpoint1 | String | Yes* | Uses route spec |
Endpoint2 | String | Yes* | Uses route spec |
Specification | String | Yes* | Uses endpoints |
Type | Specified By Full Path, Find By Endpoints, Find If Full Path Fails | Yes | None |
Multiconnect Mode | Multiconnect, No Multiconnect | Yes | None |
Comment | String Notice: Use ^t, ^r, and ^n for the tab, carriage return, and new line characters, respectively. |
No | Empty String |
Wire Mode | 1, 2, or 4 | No | Uses Endpoint1 or route specification |
Settling Time (s) | Float | No | None |
Impedance (Ohm) | Float | No | None |
Bandwidth (Hz) | Float | No | None |
DC Voltage (V) | Float | No | None |
AC Voltage (V) | Float | No | None |
DC Switching Current (A) | Float | No | None |
AC Switching Current (A) | Float | No | None |
DC Carry Current (A) | Float | No | None |
AC Carry Current (A) | Float | No | None |
DC Switching Power (W) | Float | No | None |
AC Switching Power (W) | Float | No | None |
DC Carry Power (W) | Float | No | None |
AC Carry Power (W) | Float | No | None |
* One of these is required: either both endpoints or the specification. When all three are specified, the specification is used before the endpoints.