Verifying FlexLogger Configuration

Complete the following steps to verify that your instrument is configured in FlexLogger and ready to perform a test.

  1. Confirm that all the chassis used in your system appear in the Channel Specification pane.
  2. For each channel, open the Channel Configuration pane and ensure the configuration parameters match the latest test plan.
  3. In the Channel Specification pane, confirm that live data populates for each module in your system.
    Note On large systems, it can take several minutes for the TSN network to self-configure and for modules to begin acquiring data.
  4. In the Channel Specification ribbon, confirm that the SYNC indicator appears green.
  5. From the Channel Specification pane, select all the strain channels and perform a shunt calibration.
  6. In the Logging Specification tab, ensure that you've entered the logging file path and segment parameter.