Channel Mapping Worksheet
- Updated2023-02-20
- 1 minute(s) read
Channel Mapping Worksheet
For each channel you create on the Strain-Bridge, Temperature-Thermocouple, and Voltage-Voltage worksheets, create the hardware lookup on the Channel Mapping worksheet to specify the chassis/module to which you want to add the channel.
Note the following allowed values when setting up the Channel Mapping worksheet.
- Strain-Bridge channels can only be associated with the NI-9235 and NI-9236 modules.
- Temperature-Thermocouple channels can only be associated with the NI-9213 module.
- Voltage-Voltage channels can only be associated with the NI-9213 and NI-9215 modules.
Set up the Channel Mapping worksheet with the columns described in the following table.
| Column Name | Column Type | Allowed Values |
|---|---|---|
| Channel Name | Required | Channel Name specified in the Strain-Bridge, Temperature-Thermocouple, or Voltage-Voltage worksheets. |
| Device Model | Required |
|
| Device Name | Required | Unique string, such as cDAQ1 |
| Device Serial Number | Optional | Unique string that maps to the chassis serial number, such as 123ALPHA |
| Module Model | Required |
|
| Module Slot Number | Required |
|
| Channel Number | Required |
|