Power Input

The sbRIO-9687 interface board must be powered with a +24 V DC supply. The power supply should have a maximum output current higher than the current consumption of the interface board and all attached inverters. Refer to the sbRIO-9687 Specifications for maximum current consumption.

The sbRIO-9687 power input is protected against reverse polarity, and it uses a 10 A fuse to provide protection for overcurrent. Littlefuse Series 314 is recommended, but any compatible fuse can be used. Refer to the sbRIO-9687 Specifications for maximum fuse rating.

Caution Disconnect the main +24 V supply before replacing the fuse.
Connector Pin Signal Name
1 GND
2 +24 V