Specifies the active edge for the Start Trigger. This property is used when the Start Trigger Type property is set to Digital Edge. To set this property, the NI-RFSG device must be in the Configuration state.

PXIe-5654/5654 with PXIe-5696: The Start Trigger is valid only with a timer-based list when RF list mode is enabled.

Supported Devices: PXIe-5644/5645/5646, PXIe-5654/5654 with PXIe-5696, PXI-5670/5671, PXIe-5672/5673/5673E, PXIe-5820/5830/5831/5832/5840/5841/5842/5860

Default Value: Rising Edge

Related Topics

Start Trigger

Digital Edge Trigger

Remarks

The following table lists the characteristics of this property.

Short Name StartTrig.DigEdge.Edge
Data type ci32.png
Permissions Read/Write
High-level VIs niRFSG Configure Trigger
Channel-based No
Resettable Yes
Rising Edge 0

Occurs when the signal transitions from low level to high level.

Falling Edge 1

Occurs when the signal transitions from high level to low level.