Specifies the active edge for the Script Trigger. This property requires that you use the Active Channel property to specify the name of the Script Trigger you are configuring. This property is used when Script Trigger Type property is set to Digital Edge.

To set this property, the NI-RFSG device must be in the Configuration state.

Supported Devices: PXIe-5644/5645/5646, PXI-5670/5671, PXIe-5672/5673/5673E, PXIe-5820/5830/5831/5832/5840/5841/5842/5860

Related Topics

Script Trigger

Digital Edge Trigger

Remarks

The following table lists the characteristics of this property.

Short Name ScriptTrig.DigEdge.Edge
Data type ci32.png
Permissions Read/Write
High-level VIs niRFSG Configure Trigger
Channel-based Yes
Resettable Yes
Rising Edge 0

Occurs when the signal transitions from low level to high level.

Falling Edge 1

Occurs when the signal transitions from high level to low level.