Arb:Write Waveform Burst Detection:Power Threshold
- Updated2025-10-14
- 1 minute(s) read
Specifies the relative power level at which burst start or stop locations are detected. The threshold is relative to the peak power in the waveform. NI-RFSG detects burst start (or burst stop) locations when the signal exceeds (or falls below) the level specified by this property. This property is ignored when you disable the Write Waveform Burst Detection property or when you set the Write Waveform Burst Detection Mode property to Auto.
Units: dB
Default Value: 0
Supported Devices: PXIe-5820/5830/5831/5832/5840/5841/5842
Remarks
The following table lists the characteristics of this property.
| Short Name | Power Threshold |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Channel-based | Yes |
| Resettable | Yes |