Device Specific:Vector Signal Transceiver:Signal Path:Output Port
- Updated2025-10-14
- 2 minute(s) read
Specifies the connector(s) to use to generate the signal. To set this property, the NI-RFSG device must be in the Configuration state.
You must write complex I and Q data for all options. The Q data has no effect if you set this property to I Only and set the IQ Out Port Carrier Frequency property to 0. If you set the IQ Out Port Carrier Frequency property to a value other than 0, the onboard signal processing (OSP) frequency shifts I and Q as a complex value and outputs the real portion of the result on the I connector(s) of the device.
If you set the Output Port property to I Only or IQ Out, the IQ Out Port Terminal Configuration property applies.
Supported Devices: PXIe-5644/5645/5646, PXIe-5820/5830/5831/5832/5840/5841/5842/5860
Default Values:
PXIe-5644/5645/5646, PXIe-5830/5831/5832/5840/5841/5842/5860: RF Out
PXIe-5820: IQ Out
Remarks
The following table lists the characteristics of this property.
| Short Name | Output Port |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Channel-based | No |
| Resettable | Yes |
| RF Out | 14000 | Enables the RF OUT port. This value is not valid for the PXIe-5820. |
| IQ Out | 14001 | Enables the I/Q OUT port. This value is valid on only the PXIe-5645 and PXIe-5820. |
| Cal Out | 14002 | Enables the CAL OUT port. |
| I Only | 14003 | Enables the I connectors of the I/Q OUT port. This value is valid on only the PXIe-5645. |