De-embedding:Type
- Updated2025-10-14
- 1 minute(s) read
Specifies the type of de-embedding to apply to generations on the specified port. Use the Active Channel property to specify the name of the port to configure for de-embedding.
If you set this property to Scalar or Vector, NI-RFSG adjusts the instrument settings to remove the effects of the external network between the instrument and the DUT.
PXIe-5830/5832/5840/5841/5842/5860: Valid values for this property are Scalar or None.
PXIe-5831: Valid values for this property are Vector, Scalar, or None. Vector is only supported for TRX Ports in a Semiconductor Test System (STS).
Supported Devices: PXIe-5830/5831/5832/5840/5841/5842/5860
Default Value: Scalar
Remarks
The following table lists the characteristics of this property.
| Short Name | De-embedding Type |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Channel-based | Yes |
| Resettable | Yes |
| None | 25000 | De-embedding is not applied to the generation. |
| Scalar | 25001 | De-embeds the generation using only the gain term. |
| Vector | 25002 | De-embeds the generation using the gain term and the reflection term. |