Configures the amplitude settling accuracy in decibels. NI-RFSG waits until the RF power settles within the specified accuracy level after calling the niRFSG Initiate VI or niRFSG Wait Until Settled VI or prior to advancing to next step if using RF list mode.

Any specified amplitude settling value that is above the acceptable minimum value is coerced down to the closest valid value.

PXI/PXIe-5650/5651/5652: This property is for NI internal use only.

Supported Devices: PXIe-5654/5654 with PXIe-5696, PXIe-5820/5830/5831/5832/5840/5841/5842/5860

Default Values:

PXIe-5654: 4

PXIe-5654 with PXIe-5696 (ALC disabled): 4

PXIe-5654 with PXIe-5696 (ALC enabled): 0.2

PXIe-5820/5830/5831/5832/5840/5841/5842/5860: 0.5

Valid Values:

PXIe-5654: 1.5, 2, 4

PXIe-5654 with PXIe-5696 (ALC disabled): 1.5, 2, 4

PXIe-5654 with PXIe-5696 (ALC enabled): 0.2, 0.5

PXIe-5820/5830/5831/5832/5840/5841/5842/5860: 0.01 to 1

Related Topics

Amplitude Settling Times

Remarks

The following table lists the characteristics of this property.

Short Name Amplitude Settling
Data type cdbl.png
Permissions Read/Write
High-level VIs N/A
Channel-based No
Resettable Yes