Performs a hard reset on the device, which consists of the following actions:

- Signal generation is stopped.

- All routes are released.

- External bidirectional terminals are tristated.

- FPGAs are reset.

- Hardware is configured to its default state.

- All session properties are reset to their default states.

Supported Devices:PXI-5610, PXIe-5611, PXI/PXIe-5650/5651/5652, PXIe-5653/5654/5654 with PXIe-5696, PXI-5670/5671, PXIe-5672/5673/5673E

Related Topics

Thermal Shutdown


icon

Inputs/Outputs

  • civrn.png instrument handle

    instrument handle identifies your instrument session. instrument handle is obtained from either the niRFSG Initialize VI or the niRFSG Initialize With Options VI.

  • cerrcodeclst.png error in

    error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

  • iivrn.png instrument handle out

    instrument handle out passes a reference to your instrument session to the next VI. instrument handle out is obtained from the niRFSG Initialize VI or the niRFSG Initialize With Options VI.

  • ierrcodeclst.png error out

    error out contains error information. This output provides standard error out functionality.

  • Details

    During a device reset, routes of signals between this and other devices are released, regardless of which device created the route. For example, a trigger signal exported to a PXI trigger line that is used by another device is no longer exported.

    • PXI-5610, PXI-5670/5671, PXIe-5672: After calling this VI, the device requires 25 seconds before returning to full functionality. NI-RFSG enforces this condition by adding a wait, if needed, the next time you try to access the device.