RFmxWLAN OFDMModAcc Fetch Custom Gate Powers (Array) VI
- Updated2025-10-13
- 3 minute(s) read
Fetches the average and peak power of the custom gates.
Use "segment<n>/chain<k>" as the selector string to read results from this VI.

Inputs/Outputs
Selector String
—
Selector String specifies a selector string comprising of the signal name, result name, segment number, and chain number. If you do not specify the signal name, the default signal instance is used. If you do not specify the result name, the default result instance is used. The default value is "segment0/chain0". Example: "segment0/chain0" "signal::sig1/segment0/chain0" "signal::sig1/result::r1/segment0/chain0" "result::r1/segment0/chain0" You can use the RFmxWLAN Build Chain String VI to build the selector string.
Instrument Handle In
—
Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI or the RFmxInstr Initialize NIRFSA (Array) VI.
Timeout (s)
—
Timeout specifies the timeout for fetching the specified measurement. Set this value to an appropriate time, longer than expected for fetching the measurement. A value of -1 specifies that the VI waits until the measurement is complete. This value is expressed in seconds. The default value is 10.
error in (no error)
—
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Instrument Handle Out
—
Instrument Handle Out passes a reference of your RFmx session to the next VI.
Average Power Mean (dBm)
—
Average Power Mean returns an array of average powers of the custom gates. This value is expressed in dBm. When you set the OFDMModAcc Averaging Enabled property to True, this parameter returns an array of the mean of the average custom gate power results computed for each averaging count.
Peak Power Maximum (dBm)
—
Peak Power Maximum returns an array of peak powers of the custom gates. This value is expressed in dBm. When you set the OFDMModAcc Averaging Enabled property to True, this parameter returns an array of the maximum of the peak custom gate power results computed for each averaging count.
error out
—
error out contains error information. This output provides standard error out functionality. |
Selector String
—
Instrument Handle In
—
Timeout (s)
—
error in (no error)
—
Instrument Handle Out
—
Average Power Mean (dBm)
—
error out
—