OFDMModAcc:Averaging:Type
- Updated2025-10-13
- 1 minute(s) read
Specifies the averaging type for the OFDMModAcc measurement.
This property is considered only when you set the OFDMModAcc Averaging Enabled property to True and when you set the OFDMModAcc Averaging Count property is to a value greater than 1.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is RMS.
Remarks
The following table lists the characteristics of this property.
| Short Name | OFDMModAcc Averaging Type |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Resettable | Yes |
| RMS | 0 | The OFDMModAcc measurement is performed on I/Q data acquired in each averaging count. The scalar results and traces are linearly averaged over the averaging count. |
| Vector | 5 |
The acquired I/Q data is averaged across averaging count after aligning the data in time and phase using the OFDMModAcc Vector Averaging Time Alignment Enabled and OFDMModAcc Vector Averaging Phase Alignment Enabled properties, respectively. The averaged I/Q data is used for the measurement. Refer to the
Vector Averaging concept topic for more information.
Note You must ensure that the frequency reference is locked between the generator and the analyzer. |