DSSSModAcc:Acquisition Length Mode
- Updated2025-10-13
- 1 minute(s) read
Specifies whether the measurement automatically computes the acquisition length of the waveform based on DSSSModAcc properties.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is Auto.
Remarks
The following table lists the characteristics of this property.
| Short Name | DSSSModAcc Acquisition Length Mode |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Resettable | Yes |
| Manual | 0 | Uses the acquisition length specified by the DSSSModAcc Acquisition Length property. |
| Auto | 1 | Computes the acquisition length based on the DSSSModAcc Meas Offset property and the DSSSModAcc Max Meas Length property. |