Sets the stop frequency of the offset segment relative to carrier frequency. This value is expressed in Hz.

Syntax

Namespace: NationalInstruments.RFmx.WlanMX

public int SetOffsetStopFrequency(string selectorString, double value)

Remarks

This method sets the value of SemOffsetStopFrequency attribute.The default value is 11 MHz.

Parameters

NameTypeDescription
selectorStringstring

Specifies the offset number and segment number.
Example:
"segment0" or
"segment0/offset0".
You can use the BuildOffsetString(string, int) method to build the selector string.

valuedouble

Specifies the stop frequency of the offset segment relative to carrier frequency. This value is expressed in Hz.

Returns