Sets the number of data symbols to be ignored from the start of the data field for EVM computation. This value is expressed in symbols.

Syntax

Namespace: NationalInstruments.RFmx.WlanMX

public int SetMeasurementOffset(string selectorString, int value)

Remarks

This method sets the value of OfdmModAccMeasurementOffset attribute.The default value is 0.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueint

Specifies the number of data symbols to be ignored from the start of the data field for EVM computation. This value is expressed in symbols.

Returns