Sweep:Pulse:Acquisition:Delay (s)
- Updated2025-10-13
- 1 minute(s) read
Specifies the delay in the start of the pulse acquisition relative to the pulse trigger. Pulse trigger can be internal or external. When you set Pulse Trigger Type to None then the VNA creates appropriate periodic pulse triggers internally. This property is used only when you set Pulse Mode Enabled property to True and Pulse Acquisition Auto property to False. This value is expressed in seconds.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is 0 s.
Remarks
The following table lists the characteristics of this property.
| Short Name | Pulse Acquisition Delay (s) |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Resettable | Yes |