Sets whether the device asserts the trigger when the signal power is rising or when the signal power is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge.

Syntax

Namespace: NationalInstruments.RFmx.TdscdmaMX

public int SetIQPowerEdgeTriggerSlope(string selectorString, RFmxTdscdmaMXIQPowerEdgeTriggerSlope value)

Remarks

This method sets the value of IQPowerEdgeTriggerSlope attribute.The default value is Rising.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueRFmxTdscdmaMXIQPowerEdgeTriggerSlope

Specifies whether the device asserts the trigger when the signal power is rising or when the signal power is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the SetTriggerType(string, RFmxTdscdmaMXTriggerType) method to IQPowerEdge.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.