DPD:Measurement Mode
- Updated2025-10-13
- 1 minute(s) read
Specifies if the training waveform required for the extraction of the DPD model coefficients is acquired from the hardware or is configured by the user.
You do not need to use a selector string to configure or read this property for the default signal instance. Refer to the Selector Strings topic for information about the string syntax for named signals.
The default value is Acquire and Extract.
Remarks
The following table lists the characteristics of this property.
| Short Name | DPD Meas Mode |
| Data type | ![]() |
| Permissions | Read/Write |
| High-level VIs | N/A |
| Resettable | Yes |
| Acquire and Extract | 0 | The measurement acquires the training waveform required for the extraction of the DPD model coefficients from the hardware and then computes the model coefficients. In this mode, the supported DPD Models are Lookup Table, Memory Polynomial , and Generalized Memory Polynomial. |