Returns the theoretical output power at which the gain of the device drops by a compression level, specified through the AMPM Compression Point Level property, from a gain reference computed based on the value that you specify for the AMPM Compression Point Gain Ref property. This value is expressed in dBm.

You do not need to use a selector string to read this property for the default signal and result instance. Refer to the Selector Strings topic for information about the string syntax for named signals.

Remarks

The following table lists the characteristics of this property.

Short Name AMPM Results Output Compression Point (dBm)
Data type c1ddbl.png
Permissions Read Only
High-level VIs N/A
Resettable No