Specifies the order of the harmonic. This property is not used if you set the Harm Harmonics Auto Setup Enabled to True.

Frequency of Nth order harmonic = N * (Frequency of fundamental)

Use "harmonic<n>" as the selector string to configure or read this property.

The default value is 1.

Supported devices: PXIe-5665/5668

Remarks

The following table lists the characteristics of this property.

Short Name Harm Harmonic Order
Data type ci32.png
Permissions Read/Write
High-level VIs RFmxSpecAn Harm Configure Harmonic, RFmxSpecAn Harm Configure Harmonic (Array)
Resettable Yes