Gets the OFF duration values for all measured pulses. OFF duration value is the duration of the pulse for the first falling-edge and the subsequent rising-edge transition at width threshold. This value is expressed in seconds.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int GetPulseOffDuration(string selectorString, ref double[] value)

Remarks

This method gets the value of PulseResultsPulseOffDuration attribute.

Parameters

NameTypeDescription
selectorStringstring

Specifies the result name.
Example: ""
"result::r1"
You can use the BuildResultString(string) method to build the selectorString.

valueref double[]

Upon return, contains the OFF duration values for all measured pulses. OFF duration value is the duration of the pulse for the first falling-edge and the subsequent rising-edge transition at width threshold. This value is expressed in seconds.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.