SetDetectionMinimumWidth(string, double)
- Updated2025-10-13
- 1 minute(s) read
Sets the minimum pulse width time to be considered for pulse detection. Any detected pulse width time below the specified value will be ignored by the pulse detection. This value is expressed in seconds.
Syntax
Namespace: NationalInstruments.RFmx.PulseMX
public int SetDetectionMinimumWidth(string selectorString, double value)
Remarks
This method sets the value of PulseDetectionMinimumWidth attribute.The default value is 0.00000005 seconds.
Parameters
| Name | Type | Description |
|---|---|---|
| selectorString | string | Pass an empty string. The signal name that is passed when creating the signal configuration is used. |
| value | double | Specifies the minimum pulse width time to be considered for pulse detection. Any detected pulse width time below the specified value will be ignored by the pulse detection. This value is expressed in seconds. |
Returns
Returns the status code of this method. The status code either indicates success or describes a warning condition.