Gets the middle threshold level as a percentage of the pulse amplitude used to signify the mid-transition level between pulse states used for pulse width computation.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int GetWidthThresholdLevel(string selectorString, out double value)

Remarks

This method gets the value of PulseWidthThresholdLevel attribute.The default value is 50. Valid values are 0 to 100, inclusive.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueout double

Upon return, contains the middle threshold level as a percentage of the pulse amplitude used to signify the mid-transition level between pulse states used for pulse width computation.

Returns