Gets the length of the pulse data used for the phase/frequency deviation and error measurements when you set the SetFrequencyAndPhaseDeviationRangeReference(string, RFmxPulseMXPulseFrequencyAndPhaseDeviationRangeReference) method to Center.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int GetFrequencyAndPhaseDeviationRangeLength(string selectorString, out double value)

Remarks

This method gets the value of PulseFrequencyAndPhaseDeviationRangeLength attribute.The default value is 75. Valid values are 0 to 100, inclusive.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueout double

Upon return, contains the length of the pulse data used for the phase/frequency deviation and error measurements when you set the SetFrequencyAndPhaseDeviationRangeReference(string, RFmxPulseMXPulseFrequencyAndPhaseDeviationRangeReference) method to Center.

Returns