Gets the minimum pulse off duration to be ignored by the pulse detection. This value is expressed in seconds.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int GetDetectionMinimumOffDuration(string selectorString, out double value)

Remarks

This method gets the value of PulseDetectionMinimumOffDuration attribute.The default value is 0.00000005. Valid values are 0 to 0.001, inclusive.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueout double

Upon return, contains the minimum pulse off duration to be ignored by the pulse detection. This value is expressed in seconds.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.