Gets the maximum pulse width time to be considered for pulse detection. Any detected pulse width time above the specified value will be ignored by the pulse detection. This value is expressed in seconds.

Syntax

Namespace: NationalInstruments.RFmx.PulseMX

public int GetDetectionMaximumWidth(string selectorString, out double value)

Remarks

This method gets the value of PulseDetectionMaximumWidth attribute.The default value is 0.005 seconds.

Parameters

NameTypeDescription
selectorStringstring

Pass an empty string. The signal name that is passed when creating the signal configuration is used.

valueout double

Upon return, contains the maximum pulse width time to be considered for pulse detection. Any detected pulse width time above the specified value will be ignored by the pulse detection. This value is expressed in seconds.

Returns

Returns the status code of this method. The status code either indicates success or describes a warning condition.